TECHNICAL SPECIFICATIONS - POWER WAVE 455 (K1517-6)

OUTPUT

RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT

PHYSICAL DIMENSIONS

TEMPERATURE RANGES

INPUT AT RATED OUTPUT - THREE PHASE ONLY

INPUT VOLTS

208/230/460/575V - 60HZ.

200/220/440/575V - 50HZ.

OPEN

CIRCUIT

VOLTAGE

75 VDC

INPUT

VOLTAGE /

FREQUENCY

208/50/60HZ
230/50/60HZ
460/50/60HZ
575/50/60HZ

HEIGHT

26.10 in

663 mm

WIDTH

19.86 in

505 mm

DEPTH

32.88 in

835 mm

WEIGHT

286 lbs.

130 kg.

TYPE 75°C

(SUPER LAG)

OR BREAKER

SIZE (AMPS)

110
100

50
40

TYPE 75°C

GROUND WIRE IN CON-

DUIT AWG[IEC] SIZES

(MM2)

6(16)
6(16)
10(6)
10(6)

TYPE 75°C

COPPER WIRE IN

CONDUIT AWG[IEC]

SIZES (MM2)

4(25)
4(25)
8(10)
10(6)

PROCESS CURRENT RANGES (DC)

MIG/MAG

FCAW

SMAW

Pulse

CURRENT

50-570 Average Amps
40-570 Average Amps
30-570 Average Amps

5-750 Peak Amps

PULSE

VOLTAGE

RANGE

5 - 55 VDC

AUXILIARY POWER

(CIRCUIT BREAKER PROTECTED)

40 VDC AT

10 AMPS

115VAC AT

10 AMPS

PULSE AND

BACKGROUND

TIME RANGE

100 MICRO SEC. -

3.3 SEC.

CURRENT

RANGE

Amps

5 - 570

PULSE

FREQUENCY

0.15 - 1000 Hz

INPUT

CURRENT

AMPS

58/53/25/22
82/78/37/31

49/45/23/18
67/61/31/25

IDLE

POWER

400 Watts

Max.

POWER FACTOR

@ RATED OUPUT

.95 MIN.

EFFICIENCY

@ RATED

OUPUT

88%

OUTPUT

CONDITIONS

[email protected]%

570A@43V. 60%

[email protected]%

500A@40V. 60%

OPERATING TEMPERATURE RANGE

-20°C to +40°C

STORAGE TEMPERATURE RANGE

-40°C to +40°C