Installation – Lincoln Electric IM594 PRO-CUT 20 User Manual
Page 7

A-1
INSTALLATION
A-1
Weight
Including Machine
Torch Cable (Length)
34.8 lbs.
15.8 kg.
INPUT - SINGLE PHASE / 60 HERTZ ONLY
RATED OUTPUT
OUTPUT
RECOMMEND INPUT WIRE AND FUSE SIZES
REQUIRED GAS FLOW RATE
REQUIRED GAS INLET PRESSURE
PHYSICAL DIMENSIONS
TECHNICAL SPECIFICATIONS - PRO-CUT 20 (K1579-1)
Standard Voltage
Duty Cycle
20% Duty Cycle
Current
Range
12-20 Amps
AC Input
Voltage at
60 Hertz
1Ш - 115
1Ш - 230
Fuse
(Super Lag)
Circuit Breaker
(Delay Type)
20 AMPS
20 AMPS
#14 (3.2mm
2
)
#14 (3.2mm
2
)
2 Input Supply Wires
1 Ground Wire
#14 (3.2mm
2
)
#14 (3.2mm
2
)
Type 75
o
C
Copper Wire in Conduit AWG (IEC) Sizes
Depth
16.1 in.
410 mm
Width
6.3 in.
160 mm
Height
10.2 in.
260 mm
Open Circuit
Voltage
400 VDC
For all plasma cutting applications
Based on U.S. National Electrical Code
Ambient Temperature 30
o
C or Less
Pilot Current
15 Amps @ 50% Duty Cycle
AMPS
20
VOLTS
90
1Ø Input Current at Rated Output
115/230/1/60Hz
115: 34A@20%
230: 18A@20%
65 PSI @ 240 SCFH
( 4.4 Bar. @ 10160 LHR)
80 to 150 PSI
( 5.4 Bar. TO 10.2 Bar.)