A-1

INSTALLATION

A-1

Weight

Including Machine

Torch Cable (Length)

(25ft/7.6m) (50ft/15.2m)

70 lbs. 85 lbs.

32 kg. 39 kg.

INPUT - SINGLE or THREE PHASE / 60 HERTZ ONLY

RATED OUTPUT

OUTPUT

RECOMMEND INPUT WIRE AND FUSE SIZES

REQUIRED GAS FLOW RATE

REQUIRED GAS INLET PRESSURE

PHYSICAL DIMENSIONS

TECHNICAL SPECIFICATIONS - PRO-CUT 55

Standard Voltage

Duty Cycle

50% Duty Cycle

100% Duty Cycle

Current

Range

25-55 Amps

AC Input
Voltage at
60 Hertz

1Ш - 230
1Ш - 460

3Ш - 230
3Ш - 460

Fuse

(Super Lag)

Circuit Breaker

(Delay Type)

70 AMPS
40 AMPS

40 AMPS
20 AMPS

#8 (8.4mm

2

)

#8 (8.4mm

2

)

#10 (5.3mm

2

)

#10 (5.3mm

2

)

Input Supply Wire

Ground Wire

#10 (5.3mm

2

)

#10 (5.3mm

2

)

#10 (5.3mm

2

)

#10 (5.3mm

2

)

Type 75

o

C

Copper Wire in Conduit AWG (IEC) Sizes

Depth

26.0 in.

660 mm

Width

11.0 in.

280 mm

Height

12.6 in.

320 mm

Open Circuit

Voltage

MAX

335 VDC

For all plasma cutting applications

Based on U.S. National Electrical Code

Ambient Temperature 30

o

C or Less

Pilot Current

18 Amps @ 100% Duty Cycle

AMPS

55
40

1Ø Input Current at Rated Output

3Ø Input Current at Rated Output

230/460/1 or 3Ø/60 Hz

230V: 55A @ 50%, 40A @ 100%
460V: 30A @ 50%, 23A @ 100%

Idle Current: 0.42 Amps, Idle Power 98 Watts

@ 230V

230V: 28A @ 50%, 21A @ 100%
460V: 17A @ 50%, 15A @ 100%

70 PSI @ 360 SCFH

( 4.8 Bar. @ 10160 LHR)

80 to 150 PSI

( 5.4 Bar. TO 10.2 Bar.)