A-1
INSTALLATION
A-1
Weight
Including Machine
Torch Cable (Length)
(25ft/7.6m) (50ft/15.2m)
70 lbs. 85 lbs.
32 kg. 39 kg.
INPUT - SINGLE or THREE PHASE / 60 HERTZ ONLY
RATED OUTPUT
OUTPUT
RECOMMEND INPUT WIRE AND FUSE SIZES
REQUIRED GAS FLOW RATE
REQUIRED GAS INLET PRESSURE
PHYSICAL DIMENSIONS
TECHNICAL SPECIFICATIONS - PRO-CUT 55
Standard Voltage
Duty Cycle
50% Duty Cycle
100% Duty Cycle
Current
Range
25-55 Amps
AC Input
Voltage at
60 Hertz
1Ш - 230
1Ш - 460
3Ш - 230
3Ш - 460
Fuse
(Super Lag)
Circuit Breaker
(Delay Type)
70 AMPS
40 AMPS
40 AMPS
20 AMPS
#8 (8.4mm
2
)
#8 (8.4mm
2
)
#10 (5.3mm
2
)
#10 (5.3mm
2
)
Input Supply Wire
Ground Wire
#10 (5.3mm
2
)
#10 (5.3mm
2
)
#10 (5.3mm
2
)
#10 (5.3mm
2
)
Type 75
o
C
Copper Wire in Conduit AWG (IEC) Sizes
Depth
26.0 in.
660 mm
Width
11.0 in.
280 mm
Height
12.6 in.
320 mm
Open Circuit
Voltage
MAX
335 VDC
For all plasma cutting applications
Based on U.S. National Electrical Code
Ambient Temperature 30
o
C or Less
Pilot Current
18 Amps @ 100% Duty Cycle
AMPS
55
40
1Ø Input Current at Rated Output
3Ø Input Current at Rated Output
230/460/1 or 3Ø/60 Hz
230V: 55A @ 50%, 40A @ 100%
460V: 30A @ 50%, 23A @ 100%
Idle Current: 0.42 Amps, Idle Power 98 Watts
@ 230V
230V: 28A @ 50%, 21A @ 100%
460V: 17A @ 50%, 15A @ 100%
70 PSI @ 360 SCFH
( 4.8 Bar. @ 10160 LHR)
80 to 150 PSI
( 5.4 Bar. TO 10.2 Bar.)