Installation, Safety precautions – Lincoln Electric IM366 SP-100 User Manual

Page 8

Advertising
background image

Type

K462

Rated DC Output (For use on 20 ampere

90 amps @ 18 volts

branch circuit)

20% duty cycle

Maximum DC Output (For use on 25
ampere branch circuit with optional

100 amps @ 17 volts

K467 input line cord installed)

30% duty cycle

CSA Rated DC Output

63 amps @ 20 volts

(For use on 15 ampere branch circuit)

20% duty cycle

Input Power @ CSA rated Output

115 volts

AC only

60 hertz

15 amps

Maximum Open Circuit Voltage

28 volts

115 volts

Input Power @ Rated Output, AC only

60 hertz

20 amps

115 volts

Input Power @

60 hertz

Maximum Output, AC only

25 amps

Wire Speed Range

50 to 400 in./min

(1.3 to 10.2 m/min)

Wire Sizes

.023 – .030" (0.6 – 0.8 mm) Solid Steel

.035" (0.9 mm) Flux-Cored

(1)

Spool Sizes

8" OD x 2" ID x 2.2" wide

(200 mm x 50 mm x 56 mm)

4" OD x 5/8" ID x 1.7" wide

(100 mm x 16 mm x 43 mm)

Weight

54 lbs (24.3 kg)

Dimensions (H x W x D) (Less Handle)

12" x 9 3/4" x 16 1/2"

(305 mm x 248 mm x 419 mm)

SPECIFICATIONS

1)

Requires optional Innershield Welding Kit

INSTALLATION

8

SAFETY PRECAUTIONS

Read the safety precautions at the beginning of
this Operator's Manual before proceeding.

Only personnel that have read and under-
s t o o d t h e SP-100 Operating Manual should
install and operate this equipment.

Machine must be plugged into a receptacle which
is grounded per any national, local or other applic-
able electrical codes.

The SP-100 power switch is to be in the OFF
(“O”) position when installing work cable and gun
and when connecting power cord to input power.

UNPACKING THE SP-100 (K462)

Unpack the SP-100 from its carton and remove all
packing material around the SP-100. Remove the fol-
lowing loose items from the carton:

1.SP-100.
2.Gun and cable assembly

(1)

— ready to feed .025"

(0.6 mm) diameter wire (also .023 and .024 diam-
eter wire).

3.Literature envelope which contains:

a) This operating manual, and
b) A contact tip for .030" (0.8 mm) diameter wire.

4.10 ft (3.0 m) work cable.
5.Work clamp.

(1)

K474 model gun is ready to feed .035 (0.9 mm) Innershield
with conversion parts for .030 (0.8) wire.

Advertising