Accessories – Lincoln Electric IM794 SP-170T User Manual

Page 22

Advertising
background image

C-2

C-2

ACCESSORIES

INNERSHIELD (FCAW)
CONVERSION

Several changes are needed to convert the unit for
operation with the Innershield (FCAW) process. The
K549-1 or K549-2 Innershield Kits include all the nec-
essary accessories for this conversion and are provid-
ed for this purpose. The following conversions should
be made using the contents of this kit:

1. Change the output polarity to DC(

). See

Work

Cable Installation

in Installation section for details.

2. Install proper drive roll for the wire size selected.

See

Changing Drive Roll

in Maintenance section

for details.

3. Install the proper gun liner(*)and tip for the wire

size selected. See

Component Replacement

in

Maintenance section for details.

4. Remove gas nozzle (if installed) and install gasless

nozzle. To remove, simply unscrew.

5. Load wire into machine and thread into gun and

cable per

Welding Wire Loading

section.

* The factory installed gun liner will feed .025-.035
(0.6-0.9mm)

REPLACEMENT PARTS

Complete Gun and Cable Assembly

(K530-4)

Contact Tip .025” (0.6 mm)

KP2039-1

Contact Tip .030” (0.8 mm)

KP2039-2

Contact Tip .035” (0.9 mm)

KP2039-3

Contact Tip .045” (1.2 mm)

KP2039-4B1

Contact Tip-Tapered .025” (0.6 mm)

KP2052-1

Contact Tip-Tapered .030” (0.8 mm)

KP2052-2

Contact Tip-Tapered .035” (0.9 mm)

KP2052-3

Contact Tip-Tapered .045” (1.2mm)

KP2052-4B1

Liner .030/.035” (0.8/0.9 mm)

KP1937-3

Liner .035/.045” (0.9/1.2 mm)

KP1937-1

Gas Diffuser

KP2040-1

Gas Nozzle

KP1938-1

Gas Nozzle-Tip Recessed 3/8” (9.5 mm)
Opening I.D.

KP1942-1

Gas Nozzle-Tip Recessed 1/2” (12.7 mm)
Opening I.D.

KP1942-2

Gas Nozzle-Tip Recessed 5/8” (15.9 mm)
Opening I.D.

KP1942-3

Spot Welding Nozzle

KP1956-1

Gasless Nozzle (Innershield Only)

KP1939-1

SP-170T