RANGE

SWITCH

The

Range

switch is used to select one of three

amperage ranges with generous overlap for Stick/TIG
welding, or one Wire Feed welding range.

Never change the

RANGE

Switch setting while

welding. This will damage the switch.
------------------------------------------------------------------------

CONTROL

DIAL

Provides a fine welding current adjustment within the
Range Switch settings in the STICK mode and weld-
ing voltage control with the Range switch set in the
wire feed mode.

Process Range Setting Current Range

POLARITY SWITCH

Provides three selectable welding polarities:
AC, DC+ & DC-

Never change the Polarity switch setting while
welding. This will damage the switch.
------------------------------------------------------------------------

B-2

OPERATION

B-2

CAUTION

CAUTION

KOHLER

20 H.P. COMMAND

.4 Gallons/Hour

(1.5 Liters/Hour)

.7 Gallons/Hour

(2.8 Liters/Hour)

1.2 Gallons/Hour

(4.6 Liters/Hour)

1.3 Gallons/Hour

(4.9 Liters/Hour)

1.2 Gallons/Hour

(4.5 Liters/Hour)

1.4 Gallons/Hour)

(5.3 Liters/Hour)

Low Idle - No Load

2200 RPM

High Idle - No Load
3700 RPM
AC CC Weld Output
225 Amps @ 25 Volts
DC CC Weld Output
210 Amps @ 25 Volts
DC CV Weld Output
200 Amps @ 20 Volts
Auxiliary Power
9000 Watts

WELDMARK 225 APPROXIMATE FUEL CONSUMPTION

STICK/TIG

(constant current)
(3 range settings)

WIRE FEED

(constant voltage)

(one range setting)

90 Max.

145 Max.

210DC/225AC Max.

15 to 25V

40 to 90 Amps

70 to 145 Amps

120 to 210 (DC) 225(AC)

Up to 200 Amps