SANDPIPER SPA40-E User Manual

Page 2

Advertising
background image

Model SPA1½-E and SPA40-E Design Level 3 Page 2

spa105dl3sm

TROUBLE SHOOTING

NOTE: Most common cause of failure to run is due to hardened mud and sand at

impeller. Remove strainer to check.

MOTOR WILL NOT RUN:

1. Poor connection at battery.

2. Impeller locked with foreign material.

3. Insufficient impeller clearance.

4. Damaged power cable or loose connection internally in motor assembly.

5. Bad switch or circuit breaker. Connect power leads direct to motor leads to check.

6. Worn motor brushes or out of position to make contact with armature.

PERFORMANCE LOW:

1. Strainer screen partially plugged.

2. Impeller rubbing. Check freeness of rotation with screwdriver inserted through hole

in base plated into slotted end of shaft.

3. Battery not fully charged.

4. Discharge restriction such as kinked hose or excessive discharge head.

Motor runs backwards:

1. Check wiring for correct polarity.

SERVICE AND REPAIR INSTRUCTION

DISASSEMBLY: Impeller and shaft seal can be inspected and serviced

from lower end of pump by removal of 4 capscrews securing base plate, strainer

screen, and suction cover. Screwdriver slot is provided in end of motor shaft to turn

shaft while holding impeller for removal. This permits removal of impeller without

disassembly of upper motor housing to hold motor shaft. Alternately, there is a shaft

extension with two flats on the rear of the motor for use when the impeller is difficult to

remove. The upper motor cover must be removed to expose this shaft extension.

To service motor remove 4 hex nuts and bump top cover free from housing tube.

Raise sufficiently to disconnect power cable connections. Slide housing tube up from

pump casing and motor will be exposed for service or removal.

When servicing the PortaPump and replacing the impeller (part number

444.001.010.) or suction cover (part number 258.001.157.) follow these instructions:The

impeller has been revised to typically require 1 shim (previously 7). The suction cover

has been revised to require 1 gasket (previously 5).

IMPORTANT: Make certain that wire leads are installed per diagram below.

Install top cover as indicated by arrow and instruction on top of cover. Make sure wires
do not contact motor shaft when installing motor cover.

WARRANTY

This unit is guaranteed for a period of 5 years against defective material

and workmanship.

Red Battery

Clamp

Switch

Aux

Batt

Red

Motor

Black

Black Battery

Clamp

(Ground)

Circuit Breaker

510-003-000 Compression Lug

240-001-000 Twist Clamp

Advertising
This manual is related to the following products: