m30mdl1sm-rev0713
Model M30 Metallic Page 29
To be fully groundable, the pumps must be ATEX
Compliant. Refer to pump data sheet for ordering.
This 8 foot long (244 centimeters) Ground Strap, part
number 920-025-000, can be ordered as a service
part.
To reduce the risk of static electrical sparking, this
pump must be grounded. Check the local electrical
code for detailed grounding instruction and the type of
equipment required.
Grounding The Pump
Take action to prevent static
sparking. Fire or explosion can
result, especially when handling
flammable liquids. The pump,
piping, valves, containers or other
miscellaneous equipment must
be grounded.
WARNING
one eyelet is installed to a true earth ground.
(Requires a 5/16 or 8mm maximum diameter bolt)
one eyelet is fastened to the pump hardware.