Tranquilizer – SANDPIPER Tranquilizer TA80 User Manual

Page 3

Advertising
background image

Models TA1, TA25, TA1½, TA40, TA2, TA50, TA3 & TA80

tranqmsm-rev0510

Page 1

Tranquilizer

®

• Nearly surge-free flow.

• Steadier pressures.

• Less shock to pipes.

Air-operated diaphragm pumps offer a wide range of

benefits not available in any other type of pump. However,

in some applications, pulsations in the discharge flow may

be undesirable. Pulsation can be virtually eliminated by

installing a Warren Rupp Tranquilizer®.
At initial and subsequent start-ups . . . air cushion is

quickly established by liquid pressure pushing diaphragm

upward, permitting entrance of air into air chamber, until

the balancing air cushion causes the diaphragm to center

at its mid-stroke normal operating position.
During normal continuous operation thereafter . . .

the diaphragm always flexes at its mid-range position

to absorb discharge pulsations against the adjoining air

cushion already established.
In event of change in pumped liquid pressure . . .

the air cushion pressure is automatically increased or

decreased as required to compensate for the change . .

. always maintaining constant volume of air cushion, and

the diaphragm always operating at its mid-position.
When liquid flow stops and liquid pressure is released

. . . the air in air chamber is also exhausted to atmosphere.

Tranquilizer

®

• Automatically maintains a constant volume of air cushion

for most effective surge suppression, regardless of pump

pressure.

• Automatically self-charging and self-venting to maintain

most efficient air cushion pressure . . . no more precharge

pressure calculations or guesswork, no manual

pressurizing, no periodic pressure checking.

• Air cushion separated from product by flexible diaphragm

. . . prevents product aeration.

• External visual indication provides constant evidence of

performance.

• Simple to install. Attention-free.

Models TA2 and TA50

Design Level 2

2-inch Tranquilizer

®

for use

with 1½, 2-inch pumps

Air supply connection is ¼" NPT

external pipe thread.

Maximum Operating Pressure – 125 psi.

Models TA1 and TA25

1-inch Tranquilizer

®

for use

with 1-inch pumps

Air supply connection is ¼" NPT

external pipe thread.

Maximum Operating Pressure – 125 psi.

Models TA3 and TA80

Design Level 2

3-inch Tranquilizer

®

for use

with 3-inch pumps

Air supply connection is ¼" NPT

external pipe thread.

Maximum Operating Pressure – 125 psi.

WITHOUT SUPPRESSOR

WITH SUPPRESSOR

PUMP CYCLING RATE

DISCHARGE PRESSURE

Models TA1½ and TA40

1½-inch Tranquilizer

®

for use

with 1½-inch pumps

Air supply connection is ¼" NPT

external pipe thread.

Maximum Operating Pressure – 125 psi.

Quality System

ISO9001 Certified

Environmental

Management System

ISO14001 Certified

Advertising