Specifications, Options – Schaefer Series CI User Manual

Page 2

Advertising
background image

www.schaeferpower.de

Inverters

1 or 3-Phase Output from 200VA to 45kVA, switchmode

DC / AC Inverters, AC / AC Frequency Converters & Static Switches

■

Sine Wave

■

Continuous short circuit protection

■

Thermal shutdown with auto-restart for

1-phase inverters >1.2kVA

3-phase inverters >3.6kVA

■

Suitable for complex load

■

Surge power capability

■

Industrial grade components

■

Compact and robust design

■

3-phase output: Unsymmetrical load permissible,

modular system with interchangeable inverters

■

Input voltage: 10-800V DC or

115/ 230V AC, single phase, 47-400Hz or

200/ 400/ 480V AC, three phase, 47-400Hz

■

Output voltage: 115/ 230 V AC, single phase

or 200/ 400/ 480V AC, three phases

■

Output frequency: 50/ 60/ 400/ 800Hz

(crystal stabilized) or programmable within

40-400Hz or 400-800Hz

■

Output power: 200VA - 45kVA

Features

Specifications

AC

or

DC

AC

Input

Voltage range

unit switches off at under- and
overvoltage

No-load input power

10 – 30 W

Inrush current

for AC input and DC input >160V:
limited by thermistor

Hold-up time

AC input: 10 ms typical
Series CI: 20ms typical

Immunity

acc. to EN 61000-6-2

General

Efficiency

80 – 92 %

Operating temperature

– 20 to + 75°C
optional: -40 to +75°C

Load derating

2.5%/°C above + 55°C

Storage temperature

-40 to + 85°C

Cooling
(details see page 131)

= natural convection

= incl. temperature controlled fans

Humidity

up to 95 % RH, non-condensing

Safety / Construction

acc. to EN 60950-1 / EN 50178

Protection category

IP20 acc. to EN 60529,
NEMA or others upon request

EMI

acc. to EN 61000-6-4,
class A, optionally class B

MTBF @40°C acc. to
MIL -HDBK-217E (notice1)

series IT:

120.000h

series CI:

70.000h

series IV:

50.000h

Output

Output voltages

115V AC

230V AC

3x200VAC 3x400VAC 3x480VAC

or any other

Output power

from 200 VA up to 45k VA

Line regulation (±10%)

0.1 % for series CI,
2 % for series IT and IV
3 % for series IT and IV @ 400Hz

Load regulation (10-90%)

1 % typical, 3 % max.
(400 Hz: 3 % typical, 5 % max.)

Turn-on rise time

soft-start, 100ms typical

Waveform

sine wave or any wave shape pro-
grammable by external signal

Frequency

40 – 800 Hz: adjustable or
programmable or any fixed
frequency (crystal stabilized)

Distortion

3 % typical, 5 % @ 400 Hz,
7 % @ 40 – 400 Hz, 800Hz

Overload protection
(steady state)

current limited to approx. 1.05 x
nominal current

Surge power

2 x nominal power for 1 s

Short circuit protection

electronically limited to 3 x no-
minal current, unit switches off
after 1 s

Crest factor

approx. 3

Power factor

cos 0.7 inductive / capacitive

Options

Input

■

Inrush current limiting for DC input

■

Reverse polarity protection for DC input

■

Autoranging for 115 / 230 VAC input

■

Special circuit for 16.6Hz AC input

Output

■

Remote on / off (inhibit)

■

Static Switch (details see page 97)

■

Parallel operation for redundancy or increased power:

series IT5xxx

Signals
via relay contacts

■

Power ok (input)

■

AC ok (output)

Monitoring
of input / output voltage, current or frequency via

■

analog signal

■

interface card RS232 or CAN Bus (external)

Programming
of output voltage, current or frequency via

■

potentiometer

■

analog signal

■

interface card RS232 or CAN Bus (external)

Mechanics / environment:

■

19” sub-rack for eurocassette, refer to page 121

■

Wall mount

■

Increased mechanical strength

■

Tropical protection

■

Extended temperature range to –40 °C

■

Temperature controlled fans for 19” units

Advertising