SINGLE HOSE EXHAUST & WINDOW KIT INSTALLATION

When you want quick spot cooling, install the LX-140 using the single hose window kit installation.

For Single Hose Installation

Install only the left exhaust hose over the circular air outlet (this outlet will be on the left side of the unit when
you are facing the back of the unit). Cover the right circular air intake using the exhaust intake cover. After
installing the hose remove the square air intake cover on the back of the unit and install the square air intake
vent with removable/washable filter.













For Single Hose Window Kit Installation

To install the window kit, follow the same directions on page 6 for dual hose installation, but instead of using
the dual hose window kit panel, use the single hose panel pictured below.






Exhaust Hose installed

onto circular air outlet

on left side

Exhaust cover installed

over circular air intake on

right side

Air Intake Cover

Air Intake Vent

Single Hose Window Kit Panel