Water softener trouble shooting, Just installed unit and water is not soft, Water tastes salty or brine tank fills with water – Star Water Systems Water Softener User Manual

Page 11

Advertising
background image

11

wATER SOFTENER TROublE ShOOTINg

JUST INSTALLED UNIT AND WATER IS NOT SOFT

WHAT TO CHECK

HOW TO CORRECT

Has unit been properly installed

Re-read instructions to see that all steps were followed

By-pass in plumbing

On a 3-way by-pass valve system, open valves on pip-
ing coming into and out of softener. The valve in between
MUST be closed and in good condition. Most units include
a by-pass valve which is connected to the control valve.
Make certain that it is in the service position.

Is unit piped in backwards

Check arrows where pipe threads into valve head and make
sure water is flowing consistent with the direction arrows
are pointing.

Hot water tank hardness

Allow sufficient time for hardness that has built up in your
water heater and pipes to run through system. Repeated
flushing of the water heater tank can also be done.

Is there resin in tank

Softeners ship with resin already in the tank. Make sure the
resin has not been emptied or dumped. Put a trouble light
behind resin tank and you should be able to see the resin
thru the mineral tank. The tank should be approx. 2/3 full.

Valve head is not working correctly and causing water flow
not to go through softener

Shut off water supply, de-pressurize the unit*, unscrew the
valve head from unit and exchange it.

Softener has been undersized and does not effectively re-
move the amount of hardness in your water

Draw a sample of untreated water before it goes through
the softener and a sample of treated water after the soft-
ener. Have the samples analyzed to see if any hardness is
being removed.

Water flow rate going through the softener is not allowing
time for the unit to soften

Open an outside faucet and fill a measured bucket up with
water for 1 minute. The amount of gallons in the bucket tells
you how many gallons per minute are being run through
the softener. Call 1-800-545-2206 to see what the GPM limit
is on the specific unit you have purchased. Add a flow con-
trol accessory to your unit if needed.

*To depressurize the unit, refer to valve instructions for your particular unit.

WATER TASTES SALTY OR BRINE TANK FILLS WITH WATER

WHAT TO CHECK

HOW TO CORRECT

Is backwash water flowing freely down to drain with an air
gap and no back siphoning

Put valve into “Backwash” position and follow water flow
down to drain. If over 20 ft., use 3/4” (or larger) drain tub-
ing. Drain line should be no more than 8 ft. lift.

Brine salt tube and connections not allowing salt solution
into mineral tank to regenerate

Visually check tubing for cracks or kinks. Check fittings for
proper assembly and tightness as diagrammed.

Brass
Compression
Nut

Brass
Insert

Plastic
Ferrule

Poly
Tubing

IL0707

Injector or injector screen plugged

Put softener in by-pass position and de-pressurize the unit
by putting into “Backwash” position. There will be 2 screws
on neck of valve where the salt rinse line goes into softener.
Remove the 2 screws and clean screen and remove any
chunks of salt, etc.

Advertising