Maintenance troubleshooting, Warning: disconnect power before servicing – Triangle Engineering of Arkansas CMPC User Manual

Page 3

Advertising
background image

SYMPTOM

1. Faulty switch
2. Defective motor
3. No power

Fan does not operate

1. Replace switch
2. Replace motor
3. Check to see if power cord

is plugged in. Check fuse or

circuit breaker.

POSSIBLE CAUSE(S)

CORRECTIvE ACTION

1. Loose pulleys or fan blade
2. Intake guard or exhaust

guard excessively dirty

1. Tighten pulley set screw
2. Clean guards

Insufficient air flow

1. Replace motor
2. Replace bearings and

seals

1. Defective motor bearings
2. Defective fan bearings
3. Worn belt

Squealing, slapping or whining

noises while operating

MINOR AND ROUTINE

1. Motor bearings are pre-lubricated ball

bearings. Re-lubrication is not required.

2. Keep guards and blade clean by

vacuuming or wiping periodically. Also

keep motor from accumulating excessive

dust that may cause overheating.

DISASSEMBLY PROCEDURE

1. Disconnect cord from power supply.

2. Remove guard screws.

3. Remove Guard.

NOTE: Upon completion of maintenance,

reinstall components in reverse order as

indicated above.

WHEN ORDERING REPAIR PARTS

always give the following information:
1. Part description

2. Model Number of fan

3. Serial number

MAINTENANCE

TROUBLESHOOTING

WARNING: Disconnect power before servicing

Advertising