As” series shutter installation, As” shutters – Triangle Engineering of Arkansas COMFORT COOLER User Manual

Page 2

Advertising
background image

Page 2

STEP 1. After the installation site has been

selected, clear the area of all insulation.

Establish the location of the shutter on the finished

side of the ceiling. Use the INSIDE DIMENSIONS of

the shutter and draw the four corners of the opening.

Drill a

1

/

4

" hole at each corner. Return to the attic

and inspect the area to make certain that the fan

and shutter installation area will not be obstructed

and that area is conveniently located for ease of

Tools required for installation

• Hammer

• Utility Knife or sheetrock saw

• Power or handsaw

• Pencil

• Framing square

• Straight edge

• Measuring tape

• Screwdriver

• Safety goggles

• Power or hand drill

Other materials required

• Framing lumber

• Platform lumber

• Automatic ceiling shutter

• Code required electrical materials

“AS” SERIES SHUTTER INSTALLATION

installation. Use a utility knife or sheetrock saw and

carefully cut the shutter opening. (See fig. 1).

STEP 2. From the attic side cut the ceiling joist 1

1

/

2

"

back from shutter opening. This is to accommodate

additional framing to support the joists that have

been cut. (See fig. 1).

STEP 3. Frame the opening using lumber EQUAL

TO THE EXISTING JOISTS. Attach the new framing to

the existing joists. Before fastening, make sure that

the existing joists that were cut DO NOT sag below

the uncut joists and new framing. (See fig. 2).

STEP 4. If additional framing or blocking is needed to

support the shutter, install it at this time. (See fig. 4).

STEP 5. Remove the two (2) screws that secure

the fan to the plenum. Pass the fan and plenum into

the attic through the framed opening in the ceiling

and set them aside at this time.

STEP 6. Build a platform to support the fan using

lumber, plywood or other material a minimum of

3

/

4

" thick. The platform must be constructed so that

it supports all four sides of the fan, and should be

wide enough to prevent Attic Air from being drawn

LOCATION OF FAN: The most logical place to

locate your whole house fan is near the central part

of the house. Check attic area to be certain there

is a clearance space above the fan equal to the

diameter of the fan blade. Inspect the area where

the fan is to be installed. The area must be free of

electrical wiring and pipes.

CAUTION: DO NOT OPERATE THIS FAN UNTIL

SHUTTER IS INSTALLED!

B

A

(square)

C

Fan Outside Inside

Model Size Dimension Dimension
AS10 24" 26" x 26" 24" x 24"
AS11 30" 32" x 32" 30" x 30"
AS13 30" 32" x 38" 30" x 36"
AS14 30" 34" x 36" 32" x 34"
AS15 36" 35" x 38" 33" x 36"
AS16 36" 34" x 45" 32" x 43"
AS18 42" 36" x 48" 34" x 46"
AS26 48" 38" x 58" 36" x 56"

“AS” SHUTTERS

VERTICAL INSTALLATION:

Contact the factory

for information and

instructions on vertical

installation of the

Comfort Cooler Fan.

CAUTION:

DO NOT CUT

THE SHUTTER

OPENING

THE SAME SIZE

AS THE FAN

OPENING.

Use the shutter

inside dimensions

as shown in this

chart.

C.F.M.

Blade

Weight

Dimensions

Cools

Model

H.P.

Hi-Lo

Dia.

LBS.

A

B

C

Sq. Ft.

CC 2422 1/3

5,600 / 3,700

24"

57

30" 4" 15"

up to 800

CC 3022 1/3

7,600 / 5,100

30"

62

34" 4" 15"

800 - 1,200

CC 3023 1/2

8,400 / 5,600

30"

67

34" 4" 15"

900 - 1,500

CC 3622 1/3

9,700 / 6,400

36"

77

40" 4" 15"

1,200 - 1,800

CC 3623 1/2

10,600 / 7,100

36"

82

40" 4" 15"

1,500 - 2,500

CC 4223 1/2

12,600 / 8,400

42"

91

46" 4" 15"

2,200 - 3,200

CC 4823 1/2

14,500 / 9,700

48"

107

52" 4" 15"

2,500 - 4,000

SPECIFICATIONS - FANS

STOP!

SHUTTER INSTALLATION NOTICE!!!

If you have purchased this fan with a Model “CSS”

shutter, read the section for “CSS” shutter installation

only. (See pages 4,5).

If you have purchased this fan with a Model

“AS” shutter, read the section for “AS” Shutter

installation only. (Pages 2,3).

Advertising