B - atm i – Triton ARGO G60 Installation Manual User Manual
Page 30

B-7
A
ppendix
B - ATM i
nsTAllATion
for
A
ccessiBiliTy
For a side approach, where the depth of the alcove is equal to
or less than 15 inches (380 mm), the required clear floor space
is 30 inches by 48 inches (760 mm by 1220 mm).
For a side approach, where the depth of the alcove is greater
than 15 inches (380 mm), then in addition to the 48-inch (1220
mm) length, an additional maneuvering clearance of 12 inches
(350 mm) is required.
Figures 4d. Clear Floor Space in Alcoves.
4.2.4.3 Surfaces for Wheelchair Spaces. Clear floor or ground spaces for wheelchairs shall comply with 4.5 (Ground and Floor
Surfaces).
4.2.5
Forward Reach. If the clear floor space only allows forward approach to an object, the maximum high forward reach
allowed shall be 48 inches (1220 mm) (see Fig. 5(a)). The minimum low forward reach is 15 inches (380 mm). If the high forward
reach is over an obstruction, reach and clearances shall be as shown in Fig. 5(b).
Figures 4e. Clear Floor Space in Alcove.
Figure 5a. Forward reach, unobstructed.
Figure 5b. Forward reach, obstructed.