Universal Air Tools HP180LI User Manual

Important, Operator instructions, Foreseen use of tool

Advertising
background image

Important

Read these instructions carefully before installing, operating,
servicing or repairing this tool. Keep these instructions in a safe
accessible place.

Operator Instructions

Includes - Foreseen Use, Work Stations, Putting Into Service, Operating,
Dismantling, Assembly and Safety Rules

Manufacturer/Supplier

Product Type

RPM

Cycles Per Min

Universal Air Tool Company Limited

Unit 8

Lane End Industrial Park

High Wycombe

Bucks

HP14 3BY

Tel No

Fax No

(01494) 883300

(01494) 883237

Model No/Nos

Serial No

Product Nett Weight

lbs
Kg

Recommended Use Of

Balancer Or Support

Foreseen Use Of Tool

The impact wrench is designed for the tightening and loosening of
threaded fasteners within the range as specified by the manufacturer. It
should only be used in conjunction with suitable impact type 1/2"
square female drive nut running sockets. Only use sockets which are of
the impact type.
It is allowed to use suitable extension bars, universal joints and socket
adaptors between the square output drive of the impact wrench and
the square female drive of the socket.
Do not use the tool for any other purpose than that specified without
consulting the manufacturer or the manufacturer's authorised supplier.
To do so may be dangerous.
Never use an impact wrench as a hammer to dislodge or straighten
cross threaded fasteners. Never attempt to modify the tool for other
uses and never modify the tool for even its recommended use as a
nutrunner.

Warning
Important Safety Instructions For Charger &
Battery

1. To reduce risk of injury, charge only specific type rechargeable
batteries. Other types of batteries may burst causing personal injury and
damage.
2. Before using battery charger, read all instructions and cautionary
markings on batteries, chargers and products using batteries.
3. Do not expose charger to rain or snow.
4. To reduce the risk of damage to electric plug and cord, pull by plug
rather than cord when disconnecting charger.
5. Use of an attachment not recommended or sold by the battery
charger manufacturer may result in a risk of fire, electric shock, or injury
to persons.
6. Make sure cord is located so that it will not be stepped on, tripped on,
tripped over, or otherwise subjected to damage or stress.
7. Do not operate a charger with damaged cord or plug. Replace them
immediately.
8. Do not operate charger in rain or snow.
9. To reduce risk of electric shock, unplug charger from outlet before
attempting any maintenance or cleaning. Turning off controls will not
reduce this risk.
10. Do not disassemble charger or battery cartridge, take it to a
qualified service center while repair is required. Incorrect reassembly
may result in a risk of electric shock or fire.

Additional Charger & Battery Safety Rules

1. Do not charge battery cartridge when temperature is below 0°C
(32°F) or above 40°C (104°F).
2. Do not attempt to use a set-up transformer, an engine generator or
DC power receptacle.
3. Do not allow anything to cover or clog the charger vents.
4. Always cover the battery terminals with the battery cover when the
battery cartridge is not used.
5. Do not short the battery cartridge. A battery short can cause large
current flow, overheating, possible burns and even a breakdown:
Do not touch the terminals with any conductive material.
Avoid storing battery cartridge in a container with
other metal objects such as nails, coins, etc.
Do not expose battery cartridge to water or rain,
6. Do not store the machine and battery cartridge in locations where the
temperature may reach or exceed 50°C (122°F).
7. Do not incinerate the battery cartridge even if it is severely damaged
or completely worn out. The battery cartridge can explode in a fire.
8. Be careful not drop, shake or strike battery.
9. Do not charge inside a box or container of any kind. The battery must
be placed in a well ventilated area during charging.
10. The charger should be cooled at least one hour after continuous
charging three times.

General Operational Precautions

1. Consider work area environment. Do not expose tools to rain. Do not

Work Stations

The tool should only be used as a handheld hand operated tool. It is
always recommended that the tool is used when standing on the solid
floor. It can be in other positions but before any such use, the operator
must be in a secure position having a firm grip and footing and be aware
that when loosening fasteners the tool can move quite quickly away
from the fastener being undone. An allowance must always be made
for this rearward movement so as to avoid the possibility of
hand/arm/body entrapment.

18V Lithium-Ion Cordless
1/2” Impact Wrench

HP180LI

1,800

No

7.04
3.20

Page No 1

Noise Level

Sound Pressure Level 85.2 dB(A)

Test Method

Tested in accordance with

BS EN 60745

Vibration Level

Test Method

Tested in accordance with

BS EN 60745

a =12.8 & K = 1.5 m/sec²

Personal Safety Equipment

Use - Safety Glasses

Yes

Use - Safety Gloves

Yes

Use - Safety Boots

Use - Breathing Masks

Use - Ear Protectors

Yes

2-axis test standard = 5.89 m/sec

2

Advertising