Rules, Caution – Walker Magnetics CER SERIES User Manual

Page 9

Advertising
background image

9

O.S. Walker Inc., CER Lift Magnet

RULES

MODELS: CER-5 thru CER-20 & I/R-CER-5 thru I/R-CER-12

NEVER re-energize the magnet until it has been placed in contact with the load to

be lifted. Prematurely energizing the magnet could cause unwanted materials to
be attracted to the magnet.

PERSONAL INJURY MAY RESULT.

CAUTION

3

Position the magnet so the load remains level.

4

Energize the magnet by selecting the “

LIFT

position. An indicator light will illuminate

when electrical power is applied to the

magnet. To obtain maximum lift, allow a few

seconds for the magnet to reach full power

before lifting load.

7

ALWAYS STAY

CLEAR OF THE LOAD.

Guide the load by pushing or pulling the edges.

This keeps your entire body clear of the load at all

times.

DO NOT guide the load by pushing or pull-

ing the Magnet.

NEVER get in a position where

you could get hit with load if it is dropped.

8

Carefully set the load down. De-energize

the magnet by selecting the “

DROP” posi-

tion. Hold for two to three seconds, when

released the magnet will return to the

“OFF” position. Then lift the magnet slightly

to be sure the load has been released.

Advertising