OPERATION

WARNING: Read and thoroughly understand all instructions and safety information
before operating this log splitter. Failure to do so may cause serious injury or death. Do

not allow anyone to operate this log splitter who has not read this manual. As with all power
equipment, a log splitter can be dangerous if assembled or used improperly. Do not operate this
log splitter if you have doubts or questions concerning safe operation. Call our customer service
department at 1-800-232-1195 to address these concerns.

WARNING: ALWAYS WEAR SAFETY GLASSES, SAFETY GLOVES, SAFETY
SHOES AND SUITABLE WORK CLOTHING WHEN OPERATING THIS LOG

SPLITTER. NEVER WEAR JEWELRY, NECKTIES OR OTHER LOOSE CLOTHING
WHICH COULD GET CAUGHT IN MOVONG PARTS.

WARNING: KEEP HANDS AND FEET CLEAR OF RAM AND WEDGE AT ALL
TIMES.

WARNING: KEEP AWAY FROM FLAMMABLE LIQUIDS AND GASES BEFORE
STARTING MACHINE.

BEFORE OPERATING

Select a work area

Place the log splitter on a flat, stable surface. Make sure there is sufficient room for the unsplit
logs and for the stacks of split logs. Make sure there is a safe electrical connection no more than
25 ft. from the work area.

Checking the hydraulic fluid level (Fig.4)

This log splitter has been filled with AW32 hydraulic oil at the
factory.

Warning: Lifting the log splitter is a two person
operation. Once raised, make sure the log splitter is stable

before performing any maintenance.

1. Lift up on the handle of the log splitter. Make sure the splitter

is resting securely and will not fall.

2. Loosen the fluid drain knob (1).
3. Pull out the bolt with attached dipstick.
4. Wipe the fluid off the dipstick.
5. Put the dipstick back in the fluid tank and then pull it out again.
6. Check the fluid level. It should be between the two notches (2) near the end of the dipstick.
7. Add fluid, if needed. (See below for types)
8. Replace the dipstick and tighten the fluid drain knob.

Hydraulic fluid

- Use an AW32 hydraulic fluid for operation over 40°F.

- Dexron® automatic transmission fluid for operation below 40°F.

Note: Do not mix AW32 hydraulic fluid with Dexron® automatic transmission fluid.