Ampro Corporation LITTLE BOARD P5X User Manual

Page 48

Advertising
background image

2–30

Parallel port register bit definitions (Table 2– 23):

Table 2– 23. Standard and PS/2 Mode Register Bit Definitions

Signal

Name

Full Name

Description

TMOUT

Time-out

Valid only in EPP mode , this signal goes true

after a 10

µ

S time-out has occurred on the

EPP bus. This bit is cleared by reset.

ERR*

Error

Reflects the status of the -ERROR input. 0

means an error has occurred.

SLCT

Printer selected

status

Reflects the status of the SLCT input. 1 means

a printer is on-line.

PE

Paper end

Reflects the status of the PE input. 1 indicates

paper end.

ACK*

Acknowledge

Reflects the status of the ACK input. 0

indicates a printer received a character..

BUSY*

Busy

Reflects the complement of the BUSY input. 0

indicates a printer is busy.

STB*

Strobe

This bit is inverted and output to the -STROBE

pin.

AUTOFD

Auto feed

This bit is inverted and output to the -AUTOFD

pin.

INIT*

Initiate output

This bit is output to the -INIT pin.

SELIN*

Printer select

input

This bit is inverted and output to the pin. It

selects a printer.

IRQE

Interrupt request

enable

When set to 1, interrupts are enabled. An

interrupt is generated by the positive-going -

ACK input.

PCD

Parallel control

direction

When set to 1, port is in input mode. In printer

mode, the printer is always in output mode

regardless of the state of this bit.

PD0-PD7

Parallel Data Bits

Advertising