Operation – WEN 22060 6 Gallon Horizontal Tank Air Compressor User Manual

Page 12

Advertising
background image

OPERATION


BEFORE OPERATING YOUR NEW AIR COMPRESSOR
complete the following steps.

1. Check that all nuts and bolts are secure.
2. Make sure the oil has been properly added to your Air Compressor.
3. Place your Air Compressor on a firm, level surface in a clean, dry, well ventilated area.
4. Your Air Compressor should be located 12 to 18 inches from walls or any other obstruction

which would

interfere

with

airflow.

Your

Air

Compressor

should

be

located

in

a

temperature

controlled

area

between 32°F and 95°F.

5.

Do not place rags, containers or other material on top of your Air Compressor.

Power Source Connection

Your Air Compressor is designed to operate on a properly grounded 120 volt, 60HZ, single
phase, alternating current (AC) power source with a fused 20 Amp time delayed fuse or circuit
breaker. It is recommended that a qualified electrician verify the ACTUAL VOLTAGE at the
receptacle into which the unit will be plugged and confirm that the receptacle is properly fused
and grounded. The use of the proper circuit size can eliminate nuisance circuit breaker tripping
while operating your Air Compressor. For electrical details see pages 7–9.

Initial Start-Up Procedures

1. Open

the

Air

Tank

Drain

Valve

to

permit

air

to

escape,

preventing

air

pressure

buildup

in

the

Air Tank.

2. Run the compressor for a minimum of 20 minutes in this “no-load” position to lubricate the

piston.

3. Close

Air

Tank

Drain

Valve.

Your

compressor

is

ready

for

use.

4. See pneumatic tool/equipment instructions for instructions on how to connect the

tool/equipment to your Air Compressor.

Depending on the CFM draw of the tool/equipment being operated, your new Air Compressor
can be used for operating paint sprayers, air tools/equipment, grease guns, airbrushes, caulking
guns, abrasive blasters, tire & plastic toy inflation, spraying weed killer and insecticides, etc.
Proper adjustment of the Air Pressure Regulator is necessary for all of these operations. Refer to
the air pressure specifications provided with the tool/equipment you are using.


12 

 