I. Operation

Place the scale on a horizontal flat surface.

1. Press ON/OFF key.

2. Wait until [0.0] is displayed.

3. Put the object(s) on the weighing platform.

4. Using the MODE key, you can switch between the weighing

units.

II. Tare Weighing.

1. Turn on scale as described above.

2. Place the “tare item” on the platform.

3. Press TARE and wait until [0.0] is displayed.

4. Add the “net-weight-item”.

III. Calibration

1. Turn on the scale and wait until display shows [0.0]

2. Press and hold the “CAL” button for several seconds. The

display will show [CAL], then [0.0].

3. Press the “CAL” button again and the display will show

“100.0g”.

4. Now place a 100g calibration weight onto the weighing sur-

face. Wait 5 seconds then press “CAL” again; the display will

show “PASS” and then “100.0g”.

5. Press the “ON/OFF” key to turn the scale off and remove the

weight. Calibration is complete!