American Weigh Scales CV-300 User Manual

Page 3

Advertising
background image

I. OPERATION

Place Scale on a horizontal flat surface.

1. Press [I/O] key.

2. Wait until the scale goes to zero.

3. Put the object(s) on the weighing platform.

4. Using the [M] key, you can switch between the

weighing units.

II. TARE WEIGHING

1. Turn on scale as described above.

2. Place the "tare item" on the platform. (ie tray)

3. Press [T] and wait until zero is displayed.

4. Add the "net-weight-item".

III. CALIBRATION

Calibration is NOT required before first use. Only

calibrate if scale is not weighing properly.

**Make sure you use the correct calibration weight for

your scale or the calibration will not be accurate**

CV-10: 10g calibration weight

CV-100: 100g calibration weight

CV-300: 300g calibration weight

1. Turn OFF the scale.

2. Press and hold the [M] key, then tap the

[T]. The display will show "CAL".

3. Now release both keys. The internal serial number

will display. Press [T] again to zero the scale.

4. Place the required standard calibration weight (not

Advertising