I. OPERATION

1. Press [I/O] key.

2. Wait until “0.0” is displayed.

3. Put the object(s) on the weighing platform.

4. Using the [M] key, you can switch between the

weighing units.

II. TARE WEIGHING

1. Turn on scale as described above.

2. Place the “tare item” on the platform.

3. Press [T] and wait until “0.0” is displayed.

4. Add the “net-weight-item”.

III. CALIBRATION

Calibration is NOT required before first use. Only

calibrate if scale is not weighing properly.

**Make sure you use the correct calibration weight for

your scale or the calibration will not be accurate**

1. Turn OFF the scale.

2. Press [I/O] shortly. Then immediately press and hold

[M] until “CAL” is displayed. Release the [M] key.

3. Press [M] again. Now the display reads “CAL” and

then “200g” will flash 3 times.

4. Place your 200g calibration weight on the center of

platform. Wait 3-4 seconds. The LCD display reads

“PASS”.

5. Remove the weight and press [I/O] to turn off the

scale. Finished! Repeat if needed.

Please check the availability of weights with your scale

supplier.