Panels, Click the button to add a panel, Place a check mark in the ‘installed’ checkbox – Avigilon Access Control Manager - Avigilon Workflow Guide User Manual
Page 17

13
Panels
After setting up the appliance, your next step is to configure the panels to which this appliance is
connected. For this document, we are only interested in Mercury Security panels.
To configure Mercury Security panels:
1. From the icon task bar of the home page, click on Physical Access then click on Panels.
2. Click the
button to add a panel.
The Panel Add page appears like this example:
3. Assign the new panel a name, choose an appliance, and select Mercury for vendor
type.
New fields appear like this example:
4. Place a check mark in the ‘Installed’ checkbox.
5. At the ‘Model’ pick list, select your panel model then choose your time zone.
While Mercury panels appear in this list, you can also configure Lenel panels. A table of
equivalency is shown below:
Lenel
Mercury
LNL-500
SCP-C
LNL-1000
SCP-2
LNL-2000
SCP-E
LNL-2200
EP1502
LNL-3300
EP2500
LNL-2210
EP1501
LNL-1100
MR16in
LNL-1200
MR16out
2