5.0 Focus

TM

Probe Maintenance

1. Check that alignment scribe marks are present on the flow meter as shown in Figure 13.

Figure 13: Alignment Scribe Marks on Insertion Probe Components

2. Disassemble the 3 main components of the flow meter as shown in Figure 14 by unscrewing

counterclockwise.

3. Inspect o-rings for wear and cracks and replace as necessary.

4. Inspect all thread surfaces for burrs and dirt. Deburr and clean thoroughly before reassembly.

Figure 14: Disassemble 3 Main Components to Access Optics for Cleaning




Inspect o-rings and replace if

cracked, split or worn.

Alignment Scribe Marks.

Deburr and clean threads

before reassembly

NOTE:

Ensure that scribe marks are
aligned and that L2 is toward the

tip on reassembly.