5

METER READINGS

If the LED displays:

The %MC is:

Blinking 6%

Below 5.5%

6%

Between 5.5 and 6.0

7%

Between 6.1 and 7.0

8%

Between 7.1 and 8.0

9%

Between 8.1 and 9.0

10%

Between 9.1 and 10.0

Blinking 10% and 12%

Between 10.1 and 11.0

12%

Between 11.1 and 12.0

Blinking 12% and 15%

Between 12.1 and 13.5

15%

Between 13.6 and 15.0

Blinking 15% and 17%

Between 15.1 and 16.0

17%

Between 16.1 and 17.0

Blinking 17% and 19%

Between 17.1 and 18.0

19%

Between 18.1 and 19.0

20%

Between 19.1 and 20.0

Blinking 20% and 25%

Between 20.1 and 22.5

25%

Between 22.6 and 25.0

Blinking 25% and 30%

Between 25.1 and 27.5

30%

Between 27.6 and 30.0

Blinking 30%

Above 30%

The J-Lite can be used to test many other building materials
such as drywall, plywood, OSB, MDF. Call 877-DELMHORST
(335-6467) or e-mail [email protected] for more informa-
tion on using the meter on other materials.