background image

P/N 3101569 ISSUE 3

Replacement Parts

Component

Catalog Number

Lens* - 48XBRM Series

96-L(*)

*Specify color of lens by adding one of the following letters to the catalog number: A-amber,

B-blue, G-green, or R-red, C - clear (used with white LEDs). Example: A red lens for the 48XBR

series signal is 96-LR.

Maintenance

Cleaning

Periodically clean the lens surface with a soft cloth or sponge

and water or a mild detergent solution to maintain optimum

light visibility. Ensure that the lens is completely dry before

assembling the signal.

To prevent damage to the lens, do not use

abrasive materials or cleaners.

CAUTION

Figure 4. Flash Pattern Dipswitch Settings

STEADY

(FACTORY

DEFAULT)

OFF

OFF

ON

ON

1

2

OFF

OFF

ON

ON

1

2

OFF

OFF

ON

ON

1

2

STEADY

65 FPM

Table 1. PLC Compatibility

Operating

Maximum off state

Continuous on

Surge (inrush/duration)

Cat. No.

voltage*

leakage current (mA)

current (mA)

(A/µs**)

48XBRM( )24D

24V DC

5

215

34.5/52

48XBRM( )120A

120V AC

5

108

37.5/164

*All AC volts at 50/60 Hz