Fire-Lite MS-4 Basic System Connections User Manual

Color legend, Ms-4 basic system connections, Dip switches fault leds

Advertising
background image

ON

12345678

ON

12345678

ON

12345678

TB1

TB2

TB3

TB5

TB6

TB7

J1

B+ B-

B+

B-

NAC 1

NAC 2

+

-

+

-

Nonreset Reset

B+

B-

B+

B-

ZONE 1 ZONE 2

B+

B-

B+

B-

ZONE 3 ZONE 4

C TRBL NORM

TROUBLE

C

NC NO

ALARM

SUPV

C

NC NO

J3

J5

J4

J8

J7

J9

TB8

J6

JP1

SW1

BATTERY

HOT NEUT EARTH

TRANSFORMER

1

TRANSFORMER

2

SW2

SW3

JP2

EARTH BATT CHG

CLASS A
CONVERTER

RESET

WALK

TEST

ALARM

SILENCE

ACK

SUPERVISORY

TROUBLE

MAINTENANCE

FIRE ALARM

ZONE 1

AC

POWER

NAC

DISABLE

NAC

FAULT

SYSTEM

TROUBLE

POWER

TROUBLE

WALK

TEST

ALARM

SILENCE

ZONE

DISABLE

SUPERVISORY

TROUBLE

MAINTENANCE

FIRE ALARM

ZONE 2

SUPERVISORY

TROUBLE

MAINTENANCE

FIRE ALARM

ZONE 3

SUPERVISORY

TROUBLE

MAINTENANCE

FIRE ALARM

ZONE4

ZONE

ENABLE/DISABLE

1

2

3

4

Color Legend

Initiating Device Circuit

Operating Power

Installation Information

(text)

MS-4 Basic System Connections

4.7K, ½W

ELR

4-Wire
Smoke Detector

UL Listed Supervision Relay
P/N: A77-716-01

J8 - Battery
Connection

DIP Switches

Fault
LEDs

HOT

NEUTRAL

GROUND

AC Power

120 VAC, 50/60 Hz, 2.3 Amps

CAUTION!

HIGH VOLTAGE

CAUTION

HIGH

VOL

T

AGE

DC Power Outputs (24 VDC)

Nonresettable Power - 24 VDC (500mA)
filtered, power-limited to NAC circuits.

24 VDC (500mA)

filtered, power-limited to smoke
detectors (IDC).

Resettable Power -

Initiating Device Circuits

Dummy Load all

unused circuits

as shown.

(P/N: 71245)

4.7K, ½W

ELR

NOTE: A 4XZMF Zone Relay Module can be installed
in place of the 4XLMF or 4XTMF modules.

Supervise with a power supervision relay A77-716B

Style B (Class B)
See “Waterflow/Supervisory”

Notification Appliance Circuits

Style Y (Class B) 2.5 amps max. per circuit

Resistive Contact Rating: 2.0 amps @ 30 VAC

Form-C Relays

C

NC

NO

C

NC

NO

C TRBL NORM

TB1

J2

8

7

654

3

2

1

RZA-4XF

Remote

Annunciator

4XLMF -
LED Interface Module

4XTMF -
Transmitter Module

FIRE ALARM ANNUNCIATOR

SYSTEM TROUBLE

RE-SOUND

TONE

SILENCE

Remote Alarm

Remote Trouble

Municipal Box

TB1

TBL

J1

J2

765

1

POWER

LIMITED

Filename: 51840-A0.cdr

NOTE:

A

“Class A Converter”

module can be connected

to J1 to convert the

Style B IDCs to Style D IDCs

and

Style Y NACs to Style Z NACs

CAC-4

Style B (Class B) - Zone 2 Only

B+

B-

ZONE 2

4.7K, ½W

ELR

1.2K, ½W

Resistor

T

T

W

Waterflow/Supervisory Circuit

Supervisory Switch

Supervisory Switch

Alarm Switch

For Programming of the Control Panel
refer to Instruction Manual

7 AH - 18 AH

J1 & J2 Receptacles
connect to Pins J4 & J6
on Main Circuit Board

J2 Receptacle
connects to Pins J5
on Main Circuit Board