Accuracy specifications(3) – GW Instek GDM-356 User Manual

Page 29

Advertising
background image

29

E. Resistance Test

Accuracy Specifications(3)

200

Ω

2k

Ω

20k

Ω

200k

Ω

2M

Ω

200M

Ω

Range Resolution

(0.8%+3)

Overload
Protection

Accuracy

0.1

Ω

1

Ω

10

Ω

100

Ω

1k

Ω

100k

Ω

[5%(reading-10)+10]

250V DC

or AC rms

(0.8%+1)

Remarks:
l Open circuit voltage: 700mV (At 200M

Ω

range,

it is approx. 2.8V)
l At 200M

Ω

range , test lead is in short circuit , and it

is normal to display 10 digits. During measurement,
subtract the 10 digits from the reading.

F. Frequency

Remarks: Input Sensitivity: 200mV.

G. Temperature

Range

Resolution

(3%+9)

Overload
Protection

Accuracy

250V AC

-40

o

C~0

o

C

0

o

C~400

o

C

400

o

C~1000

o

C

-40

o

F~32

o

F

32

o

F~752

o

F

752

o

F~1832

o

F

(1%+7)

(2%+10)

(3%+10)

(1%+8)

(2%+18)

1

o

C

1

o

F

1Hz

10Hz

Range Resolution Accuracy Overload Protection

2kHz

20kHz

(2%+5)

(1.5%+5)

250V AC

GDM-356