HT instruments HT4022 User Manual
Page 57

HT4020 - HT4022
EN - 24
MAX / MIN / AVG Resistance and Continuity test
Range Resolution
Accuracy
Response
time
0.0
499.9 0.1
(1.0%rdg + 5dgt)
1s
500
999
1
1000
1999
3
Instrument emits a buzzer for R<40
MAX / MIN / AVG Frequency (with test leads/ with jaws)
Range Resolution
Accuracy
Response
time
40.0
399.9Hz
0.1Hz
(0.5%rdg + 1dgt)
1s
Max
f/t =0.5Hz/s
MAX / MIN / AVG Active power, Reactive power, Apparent power
Range [kW], [kVAR], [kVA]
Resolution [kW], [kVAR], [kVA]
Accuracy
Response time
0.1
99.99
0.01
(3.5%rdg+3dgt)
1s
100.0
999.9
0.1
Accuracy defined for: sine wave, voltage 230
400V, current 1A, freq. 50-60Hz, Pf: 0.8i 0.8c
MAX / MIN / AVG Power factor
Range Resolution
Accuracy
Response
time
0.20
1.00
0.01
3°
1s
Accuracy defined for: sine wave, voltage 230
400V, current 2A, freq. 50-60Hz
6.1.1. Reference
standards
Safety: IEC/EN61010-1
Insulation: double
insulation
Pollution degree:
2
Max height of use:
2000m (6562ft)
Measurement category:
CAT III 600V between terminals and to ground
6.2. GENERAL
SPECIFICATIONS
Mechanical characteristics
Dimensions (L x W XH):
205 x 64 x 39mm (8 x 3 x 2in)
Weight (including batteries):
280g (10ounces)
Jaws opening:
30mm (1in)
Max conductor size:
30mm (1in)
Power supply
Battery type:
2x1.5V alkaline batteries type AAA LR03
Low battery indication:
Symbol
"
"
displayed
Battery life:
About 90 hours of continue measurement
Auto Power OFF:
after 5 minutes of idleness (disabled)
Display
Characteristics:
4 dgt LCD, max 9999 points, decimal point and sign
Sample rate:
64 samples in 20ms
Conversion mode:
TRMS
6.3. ENVIRONMENTAL
CONDITIONS
6.3.1. Climatic
conditions
Reference temperature:
23 ± 5°C (73 ± 41°F)
Operating temperature:
0 ÷ 40°C (32 ÷ 104°F)
Operating humidity:
<80%HR
Storage temperature:
-10 ÷ 60°C (14 ÷ 140°F)
Storage humidity:
<80%HR
This product conforms to the prescriptions of the European directive on low voltage
2006/95/EEC (LVD) and to EMC directive 2004/108/EEC
6.4. ACCESSORIES
6.4.1. Standard
accessories
Couple of test leads
ISO9000 calibration certificate
User
manual
Couple of alligator clips
Carrying
bag
Rubber cup for test lead holder Batteries