Caution – HT instruments HT9015 User Manual

Page 12

Advertising
background image

HT9014 - HT9015

EN - 11

4.3.4. Continuity test and Diode test

CAUTION

Before taking any in circuit resistance measurement, remove power from
the circuit to be tested and discharge all the capacitors.

Fig. 6: Taking Continuity test and Diode test


1. Rotate the switch on

Ω

CAP

position

2. Pushing MODE key and select continuity test. The

symbol is shown at display

3. Insert the red test lead plug into V

Ω

CAPHz%Temp

jack and the black test lead

plug into COM jack and perform continuity test on the object under test (see Fig. 6 –
left side). Buzzer emits sound if the measured resistance value is less about 60

Ω

4. Pushing MODE key and select diode test. The “

”

symbol is shown at display

5. Connect the red test leads to the anode of diode on test and the black test lead on the

cathode ones (see Fig. 6 – right side). Reverse position of test leads to reading reverse
polarization voltage

6. Displayed values within 0.4V and 0.7V (direct junction) and “OL” (reverse junction) are

correspondent to a correct result. A “0mV” value means a shorted device while a “OL”