Operation

F232201

16

* Design U6 and greater models

W6

Wash 6 (extra low agitation)

W7

Wash 7 (no agitation, drain 1 open, no
refill)

WD

Wash drain step – shortest drain time. Use
only if not followed by a spin step. Drain 1
open, no rotation.

WF

Warm flush

WH

Warm fill to high level

WM

Warm fill to medium level

WL

Warm fill to low level

WO

Warm fill to overflow level

WR

Warm rinse

•

Left dot–poor balance condition

•

Second dot from left–door lock switch

•

Third dot from left–Program Mode

•

Fourth dot from left–high level reached

•

Fifth dot from left–medium level reached

•

Right dot–low level reached

EXISTS

Cycle already in memory

EDIT?

Do you want to edit the cycle?

TEMP

Over-temperature-limit condition

OVERHT

Open or shorted temperature input circuit
or temperature out of computer’s allowable
limits

WATER

Water in washer-extractor at end of cycle

°FAR

Temperature in degrees Fahrenheit

°CEN

Temperature in degrees Centigrade

MANUAL

Manual Mode enabled

NO MAN

Manual Mode disabled

1DRAIN

One drain capability selected

2DRAIN

Second independent drain enabled (via
Auxiliary 2 output–precludes control of
recirculation pump via Auxiliary 2, if
selected). This should not be confused with
the “dual drain” option.

ADV

Advance (skip steps) feature enabled

Display Interpretations

Table 1

NO ADV

Advance feature disabled

WET CL

Wet clean function for Auxiliary 1 output
(1/2 wash speed) and Auxiliary 2 output
(recirculation pump) enabled (see
“2DRAIN.”)

NO WCL

Wet clean function for Auxiliary 1 and 2
disabled (Auxiliary 1 and 2 are timed
outputs.)

S BAL

“Short” balance routine–active only if
inverter drive load balance sensing is
utilized.

L BAL

“Long” balance routine–active only if AC
inverter drive load balance sensing is
utilized.

DRTEMP

Temperature is above 160°F in drain to
reuse tank A or B step.

BAL DR*
(flashing at
the end of
cycle)

Cycle aborted due to extreme out-of-
balance condition or door is unstable.

Display Interpretations

Table 1