H250 M40 with mounted Reed limit switches
Operating instruction
Electrical equipment for hazardous locations
Category for instrument
II2G for use in hazardous locations zone 1
Norm conformity
The electrical equipment operates as a simple device. It is in
conformity with intrinsic safety EN 60079-11:2007, para. 5.7
Ex marking
None (because it is not required in accordance to 60079-11, para. 5.7)
Reed-contact type
Bistable contact with integrated magnet
Temperature range
-40...+70°C
Insolation
500 Vac against earth
Electrical data
Only for connection to certified intrinsically safe circuits.
Peak values:
Ui = 30 V
Ii = 100 mA
Ci negligible
Li negligible
Electrical connection
For the electrical connection, first unscrew the cover. The intrinsically safe
equipment may only be connected to separated intrinsically safe circuits.
Terminals
Min contact Terminal 1 and 3
Max contact Terminal 4 and 6
General
Follow the specification and the instructions of this operation manual.