Dimension and capacity data – A.O. Smith VB/VW- 1000 User Manual

Page 4

Advertising
background image

4

Minimum clearances to combustibles:

• 4” (102mm) rear

• 0” (0mm) top & sides

• 6” (152mm) vent

TABLE 1. - GAS AND ELECTRICAL CHARACTERISTICS


Manifold Pressure

Maximum Supply Pressure

Minimum Supply Pressure

Model

Type of Gas

Inches W.C.

kPa

Inches W.C.

kPa

Inches W.C.

kPa

VB/VW-500, 750, 1000

NATURAL

-2 to -3.5

-.5 to .9

14

3.44

4.0

2.0

VB/VW-500, 750, 1000

PROPANE

-2 to -3.5

-.5 to .9

14

3.44

8.0

2.0

Minimum Pressures must be maintained during all operating conditions.

Electrical Power: 120v, 60hz, and 30 amps.


Models

VB/VW-500

VB/VW-750

VB/VW-1000

Dimensions

inches mm inches mm inches mm

Flue Outlet Diameter 6 152 6 152 6 152

Air Intake Diameter 4 102 4 102 4 102

Water Inlet

2” NPT

Water Outlet

2” NPT

Gas Inlet

1” NPT

A

56 1422 62 1575 71 1803

B

30 762 30 762 30 762

C

30 762 30 762 30 762

D

45 1143 51 1295 59 1499

E

36 914 42 1067 48 1219

F

16.5 419 16.5 419 16.5 419

G

8 203 8 203 8 203

H

15 381 15 381 15 381

J

9 229 9 229 9 229

K

11.5 292 11.5 292 11.5 292

L

11 279 11 279 11 279

M

10.5 267 10.5 267 10.5 267

N

33 838 33 838 33 838

P

31 787 31 787 31 787

DIMENSION AND CAPACITY DATA

TABLE 2. - ROUGH-IN DIMENSIONS

FIGURE 1.