Capacity and flow data – A.O. Smith VB/VW- 1000 User Manual

Page 5

Advertising
background image

5

CAPACITY AND FLOW DATA

TABLE 3. RECOVERY CAPACITIES.

TABLE 4. PUMPING PERFORMANCE GUIDE.

VB MODELS - FLOW, HEAD LOSS AND TEMPERATURE RISE

20F° (11°C) t

30F° (17°C) t

40F° (22°C) t

Maximum Flow Rate

Minimum Flow Rate

MODEL

GPM LPH P FT P m GPM LPH P FT P m GPM LPH P FT P m GPM LPH P FT P m T °F T °C GPM LPH P FT P m T °F T °C

VB-500 42 159 1.8 0.5 28 106 1.3 0.4 21 79 1.0 0.3 100 379 3.8 1.2 8 4 21 79 1.0 0.3 40 22

VB-750 63 238 2.9 0.9 42 159 2.1 0.6 32 121 1.8 0.5 110 416 4.3 1.3 12 7 32 121 1.8 0.5 40 22

VB-1000 85 322 3.9 1.2 56 212 2.8 0.9 42 159 2.3 0.7 120 454 4.9 1.5 14 8 42 159 2.3 0.7 40 22

Model

No.

Input

Rating

Btu/hr

Output

Rating

Btu/hr

Water

Flow

Temperature Rise - °F (°C)

40

60

80

90

100

120

140

(22)

(33)

(44)

(90)

(56)

(67)

(78)

VW-500

500,000

421,500

GPH

1,268

845

634

563

507

423

362

LPH

4,797

3,198

2,399

2,132

1,919

1,599

1,371

VW-700

750,000

633,750

GPH

1,901

1,268

951

845

761

634

543

LPH

7,196

4,797

3,598

3,198

2,878

2,399

2,056

VW-1000

1,000,000

845,000

GPH

2,535

1,690

1,268

1,127

1,014

845

724

LPH

9,595

6,397

4,797

4,264

3,838

3,198

2,741

Advertising
This manual is related to the following products: