products designated as 8-channel devices. Consult the
Yamaha mixing console’s documentation for additional
information about 8-channel compatibility.

Switch 9

o

N

and Switch 10 o

N

– Test Mode

Stereo Link

Mode

1 2 3 4 5 6 7 8 9 10

In Test Mode, channels 1 through 4 output a 1kHz,
48k sample rate sine wave. This mode can be used
to troubleshoot an audio system. Make sure to set the
Yamaha console’s internal sample rate to 48k when using
Test Mode.
(Note that the DIP switch handles are shown in white.)

When troubleshooting using the Y1 card Test Mode,
if the 1kHz test tones are heard in channels 1 through
4 of a connected A-Net device, this indicates that
the Y1 card is operating properly. Check the channel
routing settings in the Yamaha console user interface to
determine that audio is being routed properly.

W

arNiNg

: Before switching the Y1 card to Test

Mode, lower the volume on any connected
A-Net devices to avoid sudden volume changes
and/or possible hearing damage.

To exit the Test Mode, a console restart is required.
Power off the Yamaha mixing console. Reset the Y1 card
DIP switches to the desired operational mode position,
and then reboot the Yamaha console.

!!