SCREW TERMINAL FUNCTIONS

JUMPER LINK FUNCTIONS

V+

Positive power supply to the meter.

0V

0V power supply to the meter.

Vin

Positive measuring input, with reference to 0V.

BL+

Positive power supply to the LED backlighting.

power supply to the LED backlighting.

J1.

Not fitted:

The module has a 0 to 1V d.c. full scale range (default setting).

Fitted:

The module has a -1V to +1V d.c. full scale range.
The scale annunciators (-, 0, +) are visible. This overrides links J3 and J4.

J2.

Not fitted:

The input voltage is not inverted (default setting).

Fitted:

The input voltage is inverted inside the meter.

J3.

Not fitted:

The scale annunciators (-,0,+) are not displayed.

Fitted:

The scale annunciators (-,0,+) are displayed. This overrides link J4.

J4.

Not fitted:

The scale annunciator (0) is not displayed.

Fitted:

The scale annunciator (0) is displayed.

J BL.

Not fitted:

LED backlighting is not required or V+ exceeds 5V.

Fitted:

To switch on the LED backlighting when V+ = 5V, fit JBL to connect BL- to 0V.
If V+ exceeds 5V, then a series resistor must be fitted in the backlighting circuit. See
the application diagrams on this datasheet for details.

BL-

Negative

Page 3 of 4

www.lascarelectronics.com

SP 5-1710-BL

17 Segment Analogue LCD Meter

Specifications liable to change without prior warning

SP 5-1710-BL

Issue 1

January/2004

M.C.

Applies to SP 5-1710/2

PO Box 770, Londonderry, NH 03053 1-800-821-0023
www.martelcorp.com