PIN FUNCTIONS

1. V+

Positive power supply to the meter.

2. 0V

0V power supply connection to the meter.

3. COM Ground for analogue section of A/D converter.

It is actively held at 3.05V (nom) below V+ and must not be allowed to sink excessive current
(>100 A) by, for instance, connecting to a higher voltage.

4. IH

Positive measuring input.

5. IL

Negative measuring input.

6. DP1

Connect to 0V to display DP1 (199.9).

7. DP2

Connect to 0V to display DP2 (19.99).

8. DP3

Connect to 0V to display DP3 (1.999).

A negative supply is generated internally and mirrors the positive supply. For example: if V+ is +5V, then
the internally generated V- is -5V. When measuring with the input referenced to the same supply rail as
that of the panel meter, then the limitations on the input range are (V- + 1.5V) to (V+ - 1.5V).

LCOM

Normally Open. Connects IL to COM.