Sp 200, Pin functions, Circuit diagram – Martel Electronics SP200 User Manual

Page 3: 3½ digit backlit lcd voltmeter module

Advertising
background image

SP 200

3½ Digit Backlit LCD Voltmeter Module

PIN FUNCTIONS

1.

V+

Positive power supply to the meter and LED backlighting.

2.

NC

Not connected.

3.

GND

0V power supply connection to the meter.

4.

DP3

Connect to GND to display DP3 (199.9).

5.

DP2

Connect to GND to display DP2 (19.99).

6.

DP1

Connect to GND to display DP1 (1.999).

7.

R I

Reference voltage input for the meter's A/D converter.

8.

RO

Precision reference voltage output. Connect to RI for normal operation.

9.

BL

Connect to GND to switch on the LED backlighting.

10. COM

Ground for analogue section of A/D converter.
It is actively held at 2.8V below V+ and must not be allowed to sink excessive current
(>100 A) by, for instance, connecting to a higher voltage.

11. IH

Positive measuring input.
IH must be no closer than 1.5V to either the positive or negative supply.

12. IL

Negative measuring input.
IL must be no closer than 1.5V to the positive supply.

A negative supply is generated internally and mirrors the positive supply. For example: if V+ is +5V, then
the internally generated V- is -5V. When measuring with the input referenced to the same supply rail as
that of the panel meter, then the limitations on the input range are (V- + 1.5V) to (V+ - 1.5V).

µ

Note:

CIRCUIT DIAGRAM

Page 3 of 4

www.lascarelectronics.com

1

11

12

10

7

3

8

9

4

5

6

2

PO Box 770, Londonderry, NH 03053 1-800-821-0023
www.martelcorp.com

Advertising