V 600, Scaling, Applications – Martel Electronics V600 User Manual

Page 4: 3½ digit lcd voltmeter module

Advertising
background image

Specifications liable to change without prior warning

V 600

Issue 2

November/2001

M.C.

Applies to V 600/2

Page 4 of 4

Page 4 of 4

SCALING

Two resistors Ra and Rb

may be used to alter the

full scale reading (FSR) of

the meter - see table. The

meter will have to be re-

calibrated by adjusting the

calibration potentiometer

on the rear of the module.

+

-

Ra

Rb

INHI

Vin or in

I

INLO

FSR

Ra

Rb

2V

910k

100k

20V

1M

10k

Vin

200V

1M

1k

2000V*

1M

100R

200 A

0R

1k

2mA

0R

100R

Iin

20mA

0R

10R

200mA

0R

1R

µ

Voltage

Current

*Ensure that Ra is rated for high voltage use.

APPLICATIONS

Do not connect more than one meter to the same power supply

if the meters cannot use the same signal ground. Taking any

input beyond the power supply rails will damage the meter.

V 600

3½ Digit LCD Voltmeter Module

0V

0V

+7 to +12V

+3.5 to +6.0V

-3.5 to -6.0V

+7 to +12V

VDD

VDD

VDD

IN HI

IN HI

IN HI

IN LO

IN LO

IN LO

COM

COM

COM

ROL

ROL

ROL

ROH

ROH

ROH

RFL

RFL

RFL

RFH

RFH

RFH

15

15

15

13

13

13

11

11

11

V 600

V 600

V 600

VSS

VSS

VSS

12

12

12

DP3

DP3

DP3

5

5

5

8

8

8

7

7

7

6

6

6

10

10

10

9

9

9

±200mV

±200mV

+

+

I+

I-

-

-

Measuring an input voltage referenced to a floating supply,

i.e. the input voltage and the meter's power supply are

isolated from each other.

Measuring a single ended input referenced to supply, i.e.

the input voltage and the meter's power supply share the

same 0V rail.

Measuring a current referenced to a floating supply, i.e. the

current being measured and the meter's power supply are

isolated from each other.

Driving the Battery annunciator with associated external logic

and low battery detection circuitry.

4070

V+

V-

VDD

BP

LO BAT

TEST

15

1

11

V 600

VSS

2

14

1M

470k

1M

SET

THRESHOLD

BC 237

Normally

SHORTED

Cut to

OPEN

Normally

OPEN

Solder to

SHORT

Advertising