Dpm 3as-bl, Circuit diagram pin functions, 3‰ digit backlit lcd voltmeter module – Martel Electronics DPM 3AS-BL User Manual

Page 3

Advertising
background image

DPM 3AS-BL

3‰ Digit Backlit LCD Voltmeter Module

CIRCUIT DIAGRAM

PIN FUNCTIONS

www.lascarelectronics.com

1.

V-

Negative power supply to the meter (6.0 to 15.0V meter power supply applications only).

2.

INLO

Negative measuring input.

3.

INHI

Positive measuring input.

4.

COM

Ground for the analogue section of the A/D converter. It is actively held at 3.05V (nom.) below V+ and must not be
allowed to sink excessive current (>100 A) by, for instance, connecting to a higher voltage.

5.

REF LO

Negative input for reference voltage.

6.

REF HI

Positive input for reference voltage.

7.

GND

0V power supply to the meter (3.0 to 7.5V meter power supply applications only).

8.

V+

Positive power supply to the meter.

9.

TEST

Connect to V+ to test the LCD. Do not connect to V+ for more than a few seconds as this may damage the LCD.
TEST is held actively at 5V (nom.) below V+ and is the ground for the digital section of the meter. It can be used to
power external logic up to a maximum of 1mA.

10.

XDP

Inversion of LCD drive voltage.

11.

BAT

Low Battery annunciator drive pin. See application on the right.

This pin is not fitted as standard.

12.

L-

Negative power supply to LED backlighting.

13.

L+

Positive power supply to LED backlighting.
The backlighting is internally configured for 5V operation.
If a higher voltage is used, then add a series current limiting resistor Rs.
See Applications for calculations of Rs.

A negative supply is generated internally and mirrors the positive supply. For example: if V+ is +5V,then the internally generated V-
is -5V. When measuring with the input referenced to the same supply rail as that of the panel meter, then the limitations on the input
range are (V- + 1.5V) to (V+ - 1.5V).

LREF

Normally Closed. Enables the internal voltage reference circuit. Cut this link when using an external voltage reference.

BAT

Normally Open. Disables the Low Battery warning annunciator. Cut this link and add a low battery detection circuit

to enable the Low Battery warning annunciator via Pin 11 (BAT).

DP1

Normally Open. Close this solder link to enable decimal point DP1.

DP2

Normally Open. Close this solder link to enable decimal point DP2.

DP3

Normally Open. Close this solder link to enable decimal point DP3.

m

Note:

Solder Links:

V+

8

3

2

4

6

5

7

1

13

12

INHI

INLO

COM

REF HI

REF LO

GND

V-

L+

L-

INT

V+

V- TEST

a1

a1

27

1

26

28

29

31

30

32

34

36

35

33

d1

d1

e1

e1

f1

f1

DP1

199.9

DP2

19.99

DP3

1.999

g1

g1

f2

f2

a2

a2

g2

g2

e3

e3

b2

b2

a3

a3

f3

f3

c2

c2

b3

b3

g3

g3

d2

d2

c3

c3

ab

ab

e2

e2

d3

d3

b1

b1

c1

c1

5

2
8
6

7

13

12

25

18

11

23

17

10

16

22

9

24

19

14

15

4
3

BUF

A/Z

IN HI

IN LO

COM

CREF+

CREF-

REF HI

IC1

REF LO

LCD1

R4

R11

LED1

LED2

180k

22R

47pF

1u5

1u5

C5

C7

C6

C4

100nF

C1

47nF

R1

180k

C2

220nF

LREF

DP1

DP2

DP3

BAT

R10
100k

R9
3k

R3
1.5k

37

POL

POL

BP

COM

20
21

40

39

38

OSC3

OSC2

OSC1

10

11

9

V+

XDP

BAT

LOBAT

TEST

R8
1M

R5
100k

R2
1M

Q1
BCX19

R7
1M

R6
1M

Check Link BAT is OPEN.

V+

V+

XDP

BAT

TEST

8

10

1

V-

1M

470k

1M

4077

11

9

SET

BC 237

THRESHOLD

PO Box 770, Londonderry, NH 03053 1-800-821-0023
www.martelcorp.com

Advertising