Dpm 750s-bl, Scaling, Applications – Martel Electronics DPM750S-BL User Manual

Page 4: 3½ digit backlit lcd voltmeter module

Advertising
background image

Page 4 of 4

Page 4 of 4

Page 4 of 4

DPM 750S-BL

3½ Digit Backlit LCD Voltmeter Module

SCALING

Two resistors Ra and Rb
may be used to alter the
full scale reading (FSR) of
the meter - see table. The
meter will have to be re-
calibrated by adjusting the
calibration potentiometer
on the rear of the module.

FSR

Ra

Rb

2V

910k

100k

20V

1M

10k

Vin

200V

1M

1k

2000V*

1M

100R

200 A

0R

1k

2mA

0R

100R

in

20mA

0R

10R

200mA

0R

1R

µ

I

Voltage

Current

+

-

Ra

Rb

INHI

Vin or in

I

INLO

*Ensure that Ra is rated for high voltage use.

APPLICATIONS

Do not connect more than one meter to the same power supply if the meters cannot use the same signal
ground. Taking any input beyond the power supply rails will damage the meter.

3.0 to 7.5V Meter Power Supply

6.0 to 15.0V Meter Power

+3.0 to +7.5V

+3.0 to +7.5V

-3.0 to -7.5V

+3.0 to +7.5V

+6.0 to +15.0V

+3.0 to +7.5V

+6.0 to +15.0V

V+

V+

INHI

INHI

INLO

INLO

BL-

BL-

S

BL

S

BL

R

=

30mA

BL

V+ - 5V

R

=

30mA

BL

V+ - 5V

0V

0V

GND

V-

+

+

-

-

±200mV

±200mV

Measuring a single ended input voltage
referenced to supply, i.e. the input
voltage and the meter's power supply
share the same 0V rail. Ensure solder
link LCOM is open.

Measuring a single ended input voltage
referenced to a split supply, i.e. the input
voltage and the meter's power supply
share the same 0V rail. Ensure solder link
LCOM is open.

V+

V+

V+

V+

INHI

INHI

INHI

INHI

INLO

INLO

INLO

INLO

GND

V-

GND

V-

+

+

-

-

±200mV

±200mV

Measuring a current from a circuit which is
floating with respect to the DPM's supply,
i.e. the current and the meter's power
supply are isolated from each other. Ensure
solder link LCOM is closed.

Measuring a current from a circuit which is
floating with respect to the DPM's supply,
i.e. the current and the meter's power
supply are isolated from each other. Ensure
solder link LCOM is closed.

Measuring an input voltage referenced to a
floating supply, i.e. the input voltage and the
meter's power supply are isolated from each
other. Ensure solder link LCOM is closed.

Measuring an input voltage referenced to a
floating supply, i.e. the input voltage and
the meter's power supply are isolated from
each other. Ensure solder link LCOM is
closed.

Rb

Rb

I

+

I

+

I-

I-

1

1

1

2

2

2

4

3

3

BL-

S

BL

R

=

30mA

BL

V+ - 5V

0V

3

BL-

S

BL

R

=

30mA

BL

V+ - V- - 5V

3

BL-

S

BL

R

=

30mA

BL

V+ - 5V

0V

3

BL-

S

BL

R

=

30mA

BL

V+ - 5V

R

BL

0V

3

4

4

5

5

5

1

9

4

5

1

9

4

5

1

9

4

5

4

5

www.lascarelectronics.com

Specifications liable to change without prior warning

DPM 750S-BL

Issue 1

August/2002

M.C.

Applies to DPM 750S-BL/2

PO Box 770, Londonderry, NH 03053 1-800-821-0023
www.martelcorp.com

page 4 of 4

Advertising