Options and Accessories


Lamps -
Lamps for the Model E4 are included with the heater. Table 2-2 displays available lamps for
replacement ordering.


















(*) Standard lamp that ships in heater
(**) Lamps are for Horizontal Operation Only




Quartz Liner -
A quartz liner can be provided to protect the reflectors in the heater from contaminants, to
maintain the reflectors at their maximum efficiency. It has a 2.24 inch (57 mm) outer diameter
and a 2.09 inch (53 mm) inner diameter.

Observation Window -
A 0.5 inch diameter window (W) with a quartz cover can be provided in the center of the
chamber side wall, to permit product viewing. With the quartz cover removed, product
temperature can be measured with a suitable optical pyrometer. The observation window is not
available on models ordered with four purging ports. See Figure 3 for Window placement.

Purging Ports -
Purging ports can be provided on two (P) or four (PP) opposing sides of the chamber wall. This
feature allows the heating environment to be force-cooled or inert gas-purged. Purging ports
will not function with a quartz liner installed. See Figure 3 for purge port placement.

Table 2-2: Lamps

Model (P/N)

Heated
Length


Volts

Watts

Lamp Description

057550-002 2

Inches 120

500

Q500T3/CL

057550-003

2 Inches

120

1000

Q1000T3/4CL (*)

057541-001

5 Inches

120

500

500T3/CL (*)

057550-004

6 Inches

120

1500

Q1500T3/CL (*)

057544-002 10

Inches 240

1000

1000/T3/2CL/HT

057544-005

10 Inches

240

2000

2000/T3/CL/HT (*)

057541-004 16

Inches 240

1600

1600T3/CL

057541-008

16 Inches

240

3000

3000T3/CL (*) (**)

057541-005

25 Inches

480

2500

2500T3/CL (**)

057549-001

25 Inches

480

2500

2500T3/VB/CL (*)

057544-008

25 Inches

600

5000

5MT3/1CL/HT (**)

057541-006

38 Inches

570

3800

3800T3/CL (**)

057549-002

38 Inches

570

3800

3800T3/VB/CL (*)

Advertising