106687-001

Rev.

2

6-1

Section 6 – MAINTENANCE

The repair and maintenance of the Model 5194 includes replacement of the T3-style lamp
and quartz window and cleaning of the reflector.

6.1 LAMP

REMOVAL/REPLACEMENT/INSTALLATION: The T3-style lamp

is installed into the Model 5194 heater when shipped from the factory. The following
procedure details the process to replace the lamps in the Model 5194 (reference Figure 6-
1, 6-2, & 6-3):

Note:

• Remove all power from the heater BEFORE attempting to install/replace the

lamp.

• Allow a minimum of ½-inch (12 mm) of slack in the lamp lead so that the lead

is not taut when inserted into the lamp terminal block.

• Always take care to handle all lamps by the ceramic end seals and use clean

cotton or latex gloves to prevent contamination of the quartz lamp envelope.

1. Remove end-cover screws (2 per end cover).
2. Remove end covers on both ends of the heater.



Figure 6-1. Model 5194 End Cover Removal.

Advertising