쪽 14, Alarm out (5pin) 3 – Revo REXT600-1 User Manual

Page 13

Advertising
background image

- 8 -

CONTROL AND CONNECTIONS/DAY&NIGHT

INPUT / ALARM OUT TERMINALS - (UTP MODEL)

1

2

3

4

TP VIDEO OUTPUT

D&N

COM

IN

GND

5

ALARM

OUT

6

7

RS 485+(RX)

RS-485

RS 485-(TX)

CLASS 2

+ DC 12V -

~ AC 24V ~

This terminal accepts a DC12V or AC24V power

source from a DC12V or AC24V ac +/-10% 60/50Hz +/- 1Hz.

Use Certified/Listed Class 2 power supply only.

In DC power, use the Adapter mode than DC 12V

500mA Capacity.

4) POWER INPUT TERMINAL

5) VIDEO OUT CONNECTOR

BNC : This BNC connector provides a 1.0Vp-p/75 ohms composite video Signal.

UTP : Unshielded Twisted Pair video Transmission for effective installation(option).

1PIN : TP VIDEO OUTPUT

2PIN : TP VIDEO OUTPUT

1) CAMERA CONTROL

6 PIN : RS 485+

-

7 PIN : RS 485

2) DAY&NIGHT INPUT Terminal

To select Day/Night mode using external equipment, connect control line
to the appropriate terminal.

DAY&NIGHT EXTERNAL INPUT (2pin)

It is the function that can be switched to DAY Mode or NIGHT Mode by receiving the

D&N on/off signal from external light sensor or IR LED LAMP. When D&N Mode is set

"EXT” on the OSD menu of the camera.

) ALARM OUT (5pin)

3

Motion detection signals are output through this port. (OFF : GND, ON : 3.3V)

4

3

GND

DAY&NIGHT INPUT

Open contact : DAY

Close contact : NIGHT

<WITH UTP MODEL>

*3Pin : Only D&N with ICR model option (DDN model : NC)

(Only D&N with ICR model option)

Advertising