background image

TABLES AND DIAGRAMS

Page 1

GENERAL INFORMATION

FEATURES

Adapter mates with

2” FNPT threaded

fittings

Full-port 2” ball valve

for sensor removal

2” Adapter

removes to mount

hot-tap machine

3/4” diameter tubing

for low insertion force

IP150/250

Rotor

Rugged cast aluminum housing

18 Foot Cable

Modular electronics (optional)

• rate/total/pulse/4-20 mA

• blind 4-20 transmitter

• pulse divider

Compression nut

for easy adjustment, secure locking

Adapter fitting mates with

1-1/2” FNPT threaded fittings

Rotor housing

Removable jewel bearings for

exceptional low flow performance

IP110/210

SPECIFICATIONS*

GENERAL INFORMATION

The IP100/200-Series are adjustable depth insertion paddle-

wheels that come in brass, PVC or 316 stainless models to fit

3” to 40” pipe. Adapters mate with standard 1-1/2" (110/210)

or 2” (150/250 or PVC 110/210) NPT fittings such as saddles

and weldolets which may be purchased either locally or from

Seametrics.

Ruby bearings and a non-drag Hall-effect sensor give these meters

the widest flow range of any of the paddlewheel types. A sensor

detects the passage of miniature magnets in the six rotor blades.

The resulting square-wave signal can be sent for hundreds of

feet over unshielded cable without a transmitter and connected

directly to many PLC’s and other controls without any additional

electronics.

If desired, a modular system of electronics can be installed

directly on the flow sensor or mounted remotely. The FT415 (bat-

tery powered) and FT420 (externally powered in a splashproof cst

housing) provide digital rate and total display, as well as program-

mable pulse output; the FT420 also provides a 4-20 mA analog

output. The AO55 is a blind analog transmitter. Programmable

pulse for pump pacing is available with the PD10.

The “hot-tap” models (IP150/250) can be installed or serviced

without shutting down the line by means of a 2” full-port isolation

valve that comes with a nipple for installation on the pipe fitting.

In most circumstances, no special tool is required.

Locking collar

IP110/150

IP210/250

3” to 12” (50 - 300mm)

12” to 40” (300 - 1000mm)

Hall Effect sensor, 12 Vdc current sinking pulse

Cast aluminum

Brass or 316 SS

PVDF (Kynar)

Nickel-bound tungsten carbide (zirconia ceramic optional)

Ruby jewel

Brass/SS 110/210

Brass/SS 150/250

PVC 110/210/150/250

None

Bronze (316SS optional)

(PVC uses gate valve)

1.5” FNPT

2” FNPT

2" FNPT

0.3 - 30 feet/sec (0.1 - 9 meter/sec)

+/- 1.5% of full scale

Brass/SS

200˚ F (93˚ C) PVC 130˚ F (55˚ C)

Brass/SS

200 psi (14 bar) PVC 150 psi (10 bar)

0.44 x pressure in pipe

5-24 Vdc, 1.5 mA

#22 AWG 3-con, 18’ (6m); 2,000’ (650m) maximum cable run

Pipe Size

Sensor

Materials Housing

Sensor Body

Rotor

Shaft

Bearings

Isolation Valve

Fitting Size Required
Flow Range
Accuracy

Maximum Temperature

Maximum Pressure
Insertion Force

Power

Cable

*Specifications subject to change. Please consult our website for the most current data (www.seametrics.com).

Note: For larger pipe sizes contact factory