Rotor

Rugged cast aluminum housing

18 Foot Cable

Modular electronics (optional)

• rate/total/pulse/4-20 mA

• blind 4-20 transmitter

• pulse divider

Compression nut

for easy adjustment, secure locking

Adapter mates with 1-1/2”

FNPT threaded fittings

Rotor housing

Removable jewel bearings

TX110/210

Adapter mates

with 2” FNPT

threaded fittings

Full-port 2” ball valve

for sensor removal

2” Adapter

removes to mount

hot-tap machine

3/4” diameter tubing

for low insertion force

TX150/250

Locking collar

TABLES AND DIAGRAMS

Page 1

GENERAL INFORMATION

The TX100/200-Series are adjustable depth insertion turbines

that come in brass or 316 stainless models to fit 3” to 40”

pipe. Adapters mate with standard 1-1/2" (110/210) or 2”

(150/250) FNPT fittings such as saddles and weldolets which

may be purchased either locally or from Seametrics.

Ruby bearings and a non-drag pickoff give these adjustable

insertion turbine flow sensors a wide flow range and long life.

A sensor detects the passage of miniature magnets in the ro-

tor blades. The resulting square-wave signal can be sent for

hundreds of feet without a transmitter, over unshielded cable.

This signal can be connected directly to many PLC’s and other

controls without any additional electronics.

If desired, a modular system of electronics can be installed

directly on the flow sensor or mounted remotely. The FT415

(battery powered) or FT420 (loop powered) provides digital rate

and total display, as well as programmable pulse; the FT420

also provides a 4-20 mA analog output. The AO55 is a blind

analog (4-20 mA) transmitter. Programmable pulse for pump

pacing is available with the PD10.

The “hot-tap” models (TX150/250) can be installed or ser-

viced without shutting down the line by means of a 2” full-port

isolation valve that comes with a nipple for installation on the

pipe fitting. In most circumstances, no special tool is required.

FEATURES

SPECIFICATIONS*

Standard

Micropowered (-04 Option)

6-40 Vdc/< 2 mA

3.5-16 Vdc/60 µA @ 3.5 Vdc

Magnetoresistive

Magnetoresistive

Current Sinking Pulse

Current Sinking Pulse

100 mA max

2 mA max

3-40 Vdc

≤ Supply Voltage

TX110/150

TX210/250

3” - 12” (50 - 300mm)

12” - 40” (300 - 890mm)

Cast aluminum

Brass or 316 SS

PVDF standard

Nickel-bound tungsten carbide/Ruby

TX110/210

TX150/250

None

Bronze (316SS optional)

1-1/2” FNPT

2” FNPT

0.5 - 30 feet/sec (0.15 - 9.14 meter/sec)

+/-1.5% of full scale

200˚ F (93˚ C)
200 psi (14 bar)

0.44 x pressure in pipe

#22 AWG 3-con, 18’ (6m); 2,000’ (650m) maximum cable run

Power Source

Supply Voltage/Current

Sensor Type

Output

Sinking Current

External Pull-up Resistor

Pipe Size

Materials Housing

Sensor Body

Rotor

Shaft/Bearings

Isolation Valve

Fitting Size Required
Flow Range

Accuracy

Maximum Temperature

Maximum Pressure

Insertion Force

Cable

*Specifications subject to change. Please consult our website for the most current data (www.seametrics.com).

Note: For larger pipe sizes contact factory