MAINTENANCE and REPAIR

LT-65200186-082014

8/20/2014

Seametrics Incorporated • 19026 72nd Avenue South • Kent, Washington 98032 • USA

(P) 253.872.0284 • (F) 253.872.0285 • 1.800.975.8153 • www.seametrics.com

Rotor Replacement.

There is only one moving part to this me-

ter. The bearings are made of ruby, which rarely wears out or

needs replacement unless they have been physically damaged

by severe shock. The shaft is integrally molded into the rotor,

and shaft and rotor are replaced as one part. (You may wish

to replace the bearings, using the bearing removal tool, while

the meter is disassembled for rotor replacement). To replace

the rotor, disconnect the meter and remove the four screws

that hold the cover in place. Lift the cover and bearing plate

and remove the rotor (see parts diagram below).

When putting in the new rotor, be sure that the ends of the shaft

are in both bearings before tightening the cover. The rotor can

be easily dropped into the bottom bearing. Starting the shaft

into the upper bearing requires a bit of care. It is easier if the

rotor is spinning, which can be done by lightly blowing into a

port. When the upper bearing plate drops into place, hold it

down and check for free spinning (by blowing lightly) before

replacing the cover. Check that the O-ring is in its seat on the

bearing plate before replacing the cover. Replace the cover,

insert the four cap screws and tighten.

Sensor Replacement.

The sensor ordinarily does not need

replacement unless it is electrically damaged. If replacement is

necessary, unthread the sensor by hand. Thread the replace-

ment sensor in and tighten by hand.

SENSOR CONNECTIONS

(BLACK) Power (-)
(WHITE) Signal
(RED) Power (+) 5-24 Vdc

SES SENSOR CONNECTION

SES PARTS LISTING

1

Body, Stainless Steel

-050 (1/2 inch)

100683

-075 (3/4 inch)

100684

-100 (1 inch)

100685

2

Bearing Assembly (2 required)

100230

Bearing Removal Tool (not shown)

100372

*3

Rotor Assembly, Kynar/Carbide

100034

*4

O-Ring, Teflon-Coated Viton

100973

5

Cover (Stainless Steel) SES -050/-075

100082

5 Cover (Stainless Steel) SES -100

100800

6

Hex Screw (4 required)

100693

7

Sensor

100419

Page 4

*Alternate materials available for compatibility

with a variety of chemicals.

Reconnect the sensor according to the diagram below.

6

5

4

2

3

2

7

1