Imag accuracy, M/s), Ft/s) – Seametrics iMAG-Series User Manual
Page 6

Page 4
FLOW RANGE (3” - 12”)
Pipe Size
(Inches in diameter)
3”
4”
6”
8”
10”
12”
Max Flow Velocity
(Meters/Second)
10
10
10
10
10
10
Max Flow Rate
(Gallons/Minute)
723
1285
2891
5140
8031
11565
Max Flow Rate
(Liters/Second)
46
81
182
324
507
730
Turn Down Flow Rate
(Gallons/Minute)
3.62
6.43
14.46
25.70
40.15
57.82
Turn Down Flow Rate
(Liters/Second)
0.23
0.41
0.91
1.62
2.54
3.65
ID
inch
mm
2.60
66.04
3.12 79.25
5.05 128.27
6.44 163.58
8.61 218.69
10.55 267.97
iMAG Dimensions
iMAG
Meter Size
3”
4”
6”
8”
10”
12”
L
inch mm
12.0 305
10.24 260
12.27 312
14.24 362
18.18 462
19.68 500
H
inch mm
6.80 173
8.12 206
9.22
234
10.22 260
11.22 285
12.28 312
T
inch
mm
.68 17.3
.62
20.9
.69
23.3
.69
23.3
.69
23.3
.81
20.6
Flanges Standard ANSI 150 lb. drilling
Cable 1 lb.
Shipping Weight
pounds Kg
41 19
35
16
50 23
72 33
128 58
170 78
iMAG Accuracy
Accuracy (%)
(m/s)
0
1
2
3
4
5
33
0
5
10
15
20
25
30
(ft/s)
0
1
2
3
4
5
5
10
15
20
25
30
33
0
4
2
0
6
8
10
Flow Velocity
SPECIFICATIONS