Ar ch ive d – Seametrics AG2000 v.2 User Manual

Page 2

Advertising
background image

AG2000 Cable

(-)

(+)

AG2000

Pair 1-Black

Pair 1-Red

Pair 3-Black

Pair 3-Red

Shielded Burial Cable
3 Twisted Pairs
22 AWG Stranded

Pair 2-Black

Pair 2-Red

Blue

Orange

White

Colored Sleeves*

*Colored Sleeves readily identify the 3 pairs.

If the cable needs to be cut back, the pair

identification is printed on each wire.

Power Supply

7-24 Vdc

75 mA min

Drain Wire

Pair 1: Serial Output (Technician Use Only)
Pair 2: Pulse Output, 30 Vdc max, 10 mA max
Pair 3: External Power, 7-24 Vdc, 75 mA min
Drain: Connect to earth ground

EXTERNAL POWER

Page 2

Use the diagram below as a guideline for installing the DC30/DC35 optional input/output cable to the AG2000 meter.
(NOTE: If you ordered the input/output cable factory-installed, you may disregard this step.)

Then proceed to the appropriate wiring diagram for your application on subsequent pages.

INSTALLING THE DC30/DC35 OPTIONAL CABLE

CAUTION:

When the AG2000 is used for

regulatory purposes, ensure that regulatory
requirements are met before breaking the
security wire-and-seal. Replace wire-and-seal
according to regulatory requirements when
finished installing the DC30/DC35.

Apply Loctite Pipe Sealant

#567PST to outer half of

threads, wiping in a full

circular pattern.

Apply Loctite Pipe Sealant

#567PST to end 1/3 to 1/2

of threads, wiping in a full

circular pattern.

Partial View

(Meter Body Not Shown)

Control Connector

Discarded Parts

CAUTION:

Do Not Stress Cable

IMPORTANT:

Be sure to apply

sealant to threads

Set aside the foam battery

restraint & cover screws

DC30/DC35

Optional Input/Output Cable

AR

CH

IVE

D

(Includes Dates 7/19/06 to 1

1/06)